Intended
use
Linear drive for locking and unlocking of
standard lock-sliding fittings
- It is integrable in the fassade profile or on
the profile
Suitable for a complete remote control of
windows and flaps, in conjunction with D+H
window
drives
- Integrated electronics will control the connected
window
drive
Safety notes
Operating
voltage 24 VDC!
Do not connect directly to the mains supply!
Connection must be carried out by a certified
electrical
technician
Danger of crushing hands and fingers!
Keep people away from the operating area of
the drive
Keep children away from the control
- Use only in dry rooms
Suitable for indoor mounting only
Use
rain detector
in the event
of rain
Use unmodified original D+H parts only
Observe the bracket-set mounting instructions
Observe enclosed
red safety note!
Technical
data
Type
Rated voltage
Nominal
current
Stroke
Runtime
Service
life
Duty cycle
Housing
Ingress protection
Temp. range
Connection
Switching current drive
Loop through contacts
Forces
- Locking direction
- Unlocking direction
- Breakaway force in
unlocking direction
99.821.62
4.1/09/13
that there
is a risk
VLD51/038
24 VDC
± 20 %
38 mm
approx. 9s
> 10.000
double
strokes
30% (cycle time 10 min.)
stainless steel (V2A)
50
-50c...+500C
2,5 m silicone cable
max. 2,5A
60V/1A
500 N
max.
500 N
max.
1000
N
max.
English
Mounting
information
The VLD 51/038 can be integrated
common profiles. Please consult your D+H service
and
sales
partner
about
specifications and CAD-data
Attention:
Screw either tappet driver (PI-VLD) or
frame fittings (RE-VLD) on the VLD 51/038-BSY+
before mounting of the drive.
Functional
description
The VLD 51/038 will unlock the lock-sliding fitting,
after distribution voltage has been applied in
direction
OPEN.
After reaching the end position, the window drive
will be triggered, which will open the window then.
The window
drive will close the window,
supply voltage
has been applied
CLOSE. Continue with option lor 2.
In conjunction
Combined TMS+ and BRV signal
(TMS+ = BRV)
The BRV signal is only output when in
the end position - this prevents locking
drives and modules from malfunctioning.
Variant
1
Connection
with
window
BRV-indication.
In case
of a connected
D+H
BRV-indication,
the closed window
recognized and the VLD 51/038 will lock the lock
sliding fitting (Pages 14 + 16)
Variant
2
Connection
with
external
The function of the BRV-indication
by looping-in of a reed contact, mounted on the
window. The locking will be carried out not until the
window
drive
has disconnected
respectively the window is in its final position
(Page 15).
Scope of supply
Drive unit with 2,5 m grey silicone cable.
Dependent on the type of window, different bracket
sets are available separately.
in almost all
precise
mounting
after
in direction
with VCD 204:
drive
with
window
drive
with
will be
"CLOSED"
contact.
can be replaced
and
the drive
5/16
VLD
51/038

Werbung

loading