Maintenance
..........................................................................................................................................................
All preventive maintenance activities must be performed on a regular basis. Performing routine preventive maintenance
actions can aid in providing safe, trouble-free operation of all Tunturi New Fitness BVequipment.
Tunturi New Fitness BVis not responsible for performing regular inspection and maintenance actions for your machines.
Instruct all personnel in equipment inspection and maintenance actions and also in accident reporting and recording.
CAUTION
Wipe and clean the Tank, Rails, and the Seat Wheels with clean water.
Do not use any chemical cleaner.
Item
Seat Rails and Wheels Weekly
Frame
Tank Shell
Tank and Water
Treatment
Bungee Cord
Rowing Belt
Troubleshooting
..........................................................................................................................................................
Fault
Water changes color or
becomes cloudy.
Rower Belt slipping off
Belt/ Bungee Pulley.
Inconsistent readings on
the Monitor for 500meter
split time and SPM
(strokes per minute).
The Monitor does not
illuminate after battery
installation.
The Monitor screen
illuminates, but does not
register when rowing.
The Monitor LEVEL is not
synchronized with the
Tank LEVEL.
Time Frame
Weekly
Weekly
12 months to 2 years
Check every hundred
hours for correct tension
and for signs of wear.
Check every hundred
hours for correct tension
and for signs of wear.
Probable Cause
Rower is in direct sunlight or
has not had water treatment.
Local tap water is of poor
quality.
Bungee not under enough
tension.
Recoil not strong enough.
Sensor gap
Faulty Sensor
Sensor has moved out of
position
Wiring harness
Batteries installed incorrectly
or need replacing.
Loose or failed connection.
Sensor gap too wide
Monitor LEVEL needs to be
recalibrated.
Wipe down Side Rails and Seat Wheels with lint free cloth.
Wipe down Frame with lint free cloth.
Only use water and a clean cloth to wipe the Tank Shell.
Do NOT use any chemical cleaner to wipe the Tank Shell
Follow instructions as specified in the "Water Treatment Procedure"
section of this manual.
The Bungee Cord should last for many years. If a Bungee Cord change
is required, please contact your local service representative or go
online at www.tunturi.com for further details.
The Rowing Belt should provide many years of trouble free use.
If a Rowing Belt change is required, please contact your local service
representative or go online at www.tunturi.com for further details.
Change Rower location to reduce direct exposure to sunlight.
Add Water Treatment or change Tank water as directed in
the Water Treatment section of this manual. Consider using
distilled water to refill Tank.
Tighten Bungee Cord following the instructions in "Reattaching
the Rower Belt" section of this
manual at "Step 5".
Use the battery cover of the Monitor as a "Gap Tool" to check
the gap between Sensor Head and Magnetic Ring, or see if the
Sensor Head has moved out of position.
Please contact your nearest FLUID
customer service center for details.
Replace/reinstall batteries in correct position and try again.
If the LCD screen fails to illuminate, try rotating the batteries
slightly in the Monitor.
If this fails, contact your local service center.
Check that the Monitor lead is connected properly. If it is
connected then contact your local service center. Check Sensor
gap.
Please refer to "Calibration Procedure" page 13 of this manual.
16
Instructions
Solution