4. TECHNICAL DATA

Max. permissible current consumption by the pump
motor
Controller input voltage
Output voltage to the pump
Permissible range of controller input voltage
Input current frequency
Output current frequency range
Controlled device
Integrated pressure sensor
Permissible pressure range
Permissible flow
Ambient temperature range
Temperature of water pumped
Water pressure required for automatic start
Electrical system
Controller housing IP rating
TYPE
21
SMART FLOW S
(1-phase) 1.1 kW
8A
1~230V
1~230 V
(one phase)
1~ 200 V ÷ 240 V
50 Hz
30 ÷ 55 Hz
Pump
0.5~4.5 VDC
0,5 ÷ 10 bar
do 300 l/min
+5 ÷ +50°C
+5 ÷ +50°C
33% lower than the set pressure, but not lower
than 0.5 bar
Unconditionally effective grounding +
RCD In=30 mA
IP 55