GCGD360
GCUC100, GCUC200, GCUC300
68
5.1
Refrigerant
BEWARE
!
The refrigerant circuit of the appliance contains the refrigerant
isobutane (R600a), a highly environmentally compatible
natural gas that is inflammable. While transporting and installing
the appliance, ensure that no parts of the refrigerant circuit
are damaged.
Procedure if the refrigerant circuit is damaged:
• Avoid open fire and ignition sources at all costs
• Ensure that the room in which the appliance is located is well ventilated
6
Installation
6.1
Positioning
The appliance should be located in a well-ventilated and dry room. The
ambient temperature affects the power consumption and correct function of
the appliance.
Sufficient air circulation on the rear wall and upper edge of the appliance
must be guaranteed. For optimal ventilation of the appliance, the minimum
ventilation cross-sections must be observed: position the refrigerator at least
100 mm away from the wall; furthermore a space of 20 mm must be left to the
right and to the left, and 300 mm at the top. use the appliance on a firm and
smooth surface. All backbar units (UC100, UC200 and UC300) have spacers on
the back to ensure adequate air circulation. These units can be fully enclosed
on all sides.
69