NOTE:Thetest function accurately tests the alarm's smokesensing circuit Without
the need to test Withsmoke. Ifyour smoke alarm fails to give an audible test signal,
pleaserefer immediately to the troubleshooting guide at the endOfthis manual.
Never usean open name to test this device.
Installation
Positioning
STUDY
LIVING
BEDROOM
KITCHEN
o
BEDROOM
BASEMENT
NOTE: If a smoke alarm is installed in a kitchen, ensure it has an accessible silence
button, and install it asfar away from the stove and sink as possible to avoid false
alarms.
C)
CARBON
MONOXIDE
Q_2J ALARMS
GARAGE
O
(D FIRE EXTINGUISHER
S
o
•12
Prioritizethe installation of an alarm in the bedroom and hal ways,and
make sure you can hearthe alarm from all sleeping areas.In a home
with several bedrooms, install an alarm in every bedroom. f you instal
only one smoke alarm in your home, install the alarm nearto al
bedrooms where possible,and not in a basement or furnace room.
nstall an alarm above the stairway and on every floor of the house
2.
3. Smoke,heat and anything burning will spread horizontal y after rising
to the ceiling, so install the alarm in the middle of the ceiling where
possible. Ensurethat the alarm is installed at the minimum distance
away from corner.
f an alarm cannot be installed in the middle ofa ceiling, install it at a
4
distance of 20 inches (50cm) away from the corners of the room.
5. If an alarm is instal ed onto a wall, a distance of 4-12 inches (10-30 cm)
should be kept be ow the ceiling.
6.
f the ength ofa room or hall is beyond 30 feet (900cm), several alarms
ALARMS
shou d be installed
7. When the wall or ceiling is angled, the alarm needs to be installed
within 3 feet (90cm) of the highest wall or ceiling point (measured
horizontal y) in the room.
8. In multi-level houses or apartments, install at least one wireless smoke
alarm on each level and keep them installed in a straight vertical line
(seediagram) with asfew obstacles between each of the
interconnected alarmsas possible to ensure optimal signa
transmission.
in the same
room.