DISASSEMBLY
1) Using the tabs (PULL), push the vRC sleeve up over the tube and
pull back.
2) Relieve the tube towards the vRC fitting (short, jerky movement)
3) Fully insert the standard pull-off shells.
Pull out the tube while turning it at the same time.
4) To replace the clamping ring: If the vRC fitting is re-used, the
vRC clamping ring MUST be replaced. vonRoll recommends also
changing the O-ring seal.
5) By distorting the shape of the vRC clamping ring, press it into the
vRC fitting. Check the orientation of the clamping ring cone.