Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Range Of Use - T.I.P. GP 3600 I mit Kit Gebrauchsanweisung

Gartenpumpe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
prevented. Never hold the device under running water. Please follow the instructions
of " Maintenance and troubleshooting".
Notes and instructions with the following symbols require particular attention:
Any nonobservance of these instructions involves the danger of bodily harm to
people and/or damage to property.
Any nonobservance of this instruction bears the risk of an electrical shock which may
cause damage to persons or property.
Please inspect the device for damage occurred during transportation. In case of damage, the retailer
has to be informed immediately, at the latest within 8 days after the date of purchase.

2. Technical Data

Model
Mains voltage / frequency
Nominal performance
Protection type
Suction port
Pressure port
1)
Max. flow rate (Q
)
max
Max. pressure
1)
Max. delivery height (H
)
max
Max. suction height
Max. size of the solids being pumped
Max. permissible operating pressure
Min. ambient temperature
Max. ambient temperature
Min. fluid temperature
Max. fluid temperature (T
)
max
Max. cut-in frequency in one hour
Length of connection cable
Cable type
Weight (net)
Guaranteed sound power level (L
Measured sound power level (L
2)
Sound pressure level (L
)
pA
Dimensions (L x D x H)
Item no.
1)
The values were determined with free, unreduced in- an outlet.
2)
Noise emission values obtained according to the EN 12639 regulation. Measurement method
according to EN ISO 3744.

3. Range of use

Garden pumps from T.I.P. are highly efficient self-priming electrical pumps for discharging clear, clean
or moderately dirty water containing solids up to the maximum size specified in the technical details.
These high-quality products with their convincing performance data were developed for the multiple
purposes involved with irrigation, draining, water withdrawal as well as for the further conveyance of
water under pressure.
The typical ranges of application of garden pumps include: filling or emptying of storage containers,
basins and ponds, water withdrawal from wells or cisterns, flushing down of terraces and boardwalks.
The device is not suitable for use in swimming pools or for installation in public water mains.
10
2)
)
WA
2)
)
WA
GP 3600 I mit Kit
230 V~ 50 Hz
650 Watt
IPX4
30.93 mm
, female
(1 ")
30.93 mm
, female
(1 ")
3.600 l/h
4.0 bar
40 m
9 m
3 mm
6 bar
5 °C
40 °C
2 °C
35 °C
40, evenly distributed
1.5 m
H07RN-F
~ 7.1 kg
81 dB
78.7 dB
70.7 dB
37 x 19,5 x 28,5 cm
30177
2