Perform the filter change as follows:
1. Switch off the product at the main switch and secure it against
unintentional restart by pulling out the mains plug.
2. Provide a new main filter (item 4) and, if necessary, a new pre-filter
(item 3) + activated charcoal filter (item 5).
3. Open the maintenance door (item 1) and carefully remove the filter
elements (items 1+2) and, if present, the activated charcoal filter (item 4)
out of the product without stirring up dust.
NOTE
The pre-filter (item 3) can be used several times. In the event of
mechanical destruction of the surface, it must be changed.
4. Carefully place the saturated filter elements in a disposal bag, seal it
airtight and dispose of it according to the instructions.
5. Re-insert the new main filter (item 4), the pre-filter (item 3) and the
activated charcoal filter (item 5), if required, into the product in reverse
order, making sure that they are installed in the correct position.
6. Close the maintenance door (item 1) and put the product back into
operation. (see also chapter "Commissioning")
NOTE
Observe the information printed on the filter element when changing
the filter.