NOTE
Products with IFA certification according to requirements for W3/IFA
certified welding fume separation class. (See "Technical data" chapter)
The IFA approval becomes void if:
The product is used other than as intended or is subject to
constructive modifications.
Non-original spare parts, in accordance with the spare parts list, are
used.
Only original replacement filters, because they guarantee the necessary
filter efficiency and are matched to the product and its performance
characteristics.
Switch the product off using the on/off switch.
Secure the product against unintentional switching on. If available, pull
out the mains plug or secure the main switch in the 0 position with a
padlock.
Disconnect the pressure supply, if present, and let the compressed air
present in the product flow out via the condensate drain valve.
7.2.2 Changing filters
NOTE
The product has a pre-filter and a main filter. Some products also have an
activated charcoal filter or this can be retrofitted if required. (see chapter
"Spare parts + Accessories")
The service life of the activated charcoal filter depends on the respective
conditions of use and cannot therefore be predicted. However, the
activated charcoal filter should be replaced at the latest when the main
filter is changed.