When using AC output to power your device, press and hold the switch for about 1 second,
the LED indicator bar will light up, at this point of time, the product can power any device with
load rating within 2500W and lower.
Note:
⚫
The discharge time of POWER2GO is affected by many factors such as ambient
temperature, discharge rate, battery capacity, load characteristics, etc.
⚫
When the LED bar indicator turns into red, (light usually on the right-side portion), this
means that the POWER2GO battery level is 10% or less. During this time, if high power
rating device will be used, the system may activate the protection. You are advised to
charge the POWER2GO in time.
⚫
During operation, the internal and external temperatures of the POWER2GO are
continuously monitored, and the power will be limited to 2000W when the surface
temperature reaches 50°C, and the output will be cut off when the surface temperature
reaches 60°C. At 25°C and 8.7A, the POWER2GO can be fully discharged (100%->5%)
without triggering a shutdown.
⚫
For continuous maximum load operation, devices which operates under the constant
power of 2500W can be operated by POWER2GO around more than 35 minutes as
protection will cut the operation when surface temperature reaches 60°C.
7.4 Warning
⚫
Please do not put your fingers or any metal conductor inside the AC socket to avoid
electric shock.