The DIP switches are used to set the running time
of the motor in midway mode, auto close time of
the gate opener and fast change the open/close
direction which is determined by the position of
the gate opener installed.
DIP Switch #1–#2: Running time of the motor
in Midway Mode
This mode enables user to drive the vehicle through the gate quickly when the gate opens to certain width.
DIP Switch #1: ON – 4 Seconds OFF – 0
DIP Switch #2: ON – 2 Seconds OFF – 0
NOTE: The midway mode function would be disabled if both DIP switches are turned off. Factory default
setting is disabled. The midway mode could be activated by pressing button B of the remote control
when the gate is in the full closed position.
E.g.
Running time of the operator in midway mode is 4+2=6 seconds.
DIP Switch #3–#4: Auto close time of the gate opener
DIP Switch #3: ON – 30 Seconds OFF – 0
DIP Switch #4: ON – 60 Seconds OFF – 0
NOTE: The auto close function would be disabled if both dip switches are turned to off (factory default
setting).
E.g.
Auto close time of the gate operator is 30+60=90 seconds.
Important Note: When the auto close function is enabled, the photocell sensor is highly
recommended to be installed with the gate opener for safety.
DIP Switch #5: Left/Right open
ON – Left open (factory default setting).
OFF – Right open. Turn switch OFF to change the opening direction easy if necessary.
2. Potentiometers
The potentiometer A is to adjust the OPEN stall force of the gate opener. The Potentiometer B is used to adjust