INSTALLATION

Fig.1 - DIMENSIONS (mm):
85
IMPORTANT: - The installation of this device must be carried out by specialized technicians.
- Caution, do not connect the battery charger:
when a generator set with non stabilised output voltage is employed
1
with power mains voltage exceeding the rated value (230V
1
- Do not carry out any maintenance when the battery charger is connected to the
230V
- In case of battery charger's misuse, the guarantee falls off and the manufacturer
declines all responsibility for damages to people and things.
-This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
BATTERY CHARGER
- Install the battery charger in an appropriate housing, dry and ventilated; maximum efficiency can be
obtained when the battery charger is installed in vertical position (see figure 2), keeping the front side
at minimum distance of 300 mm and the bottom and top side at a minimum distance of 100 mm from
the housing sides.
- Do not cover air intakes.
- To guarantee a proper change of air the installation of two air intakes (one placed on the top and one
on the bottom, see figure 2) ensuring a working temperature inside the housing not exceeding 50 °C.
- Make sure that the 230V
- The connection to power supply mains shall be made in accordance with national installation rules.
- Before disconnecting the battery charger from 230V
- The installation requires the fixing of no. 4 pins that can be easily placed on the 4 sides.
- The battery charger can be installed together with CBE 12V and 230V distribution panels, using the
appropriate modular joints.
CABLES
- Mains connection: use a 3x1.5mm² cable, type H05 RN-F or equivalent.
- Battery connection: use N07 V-K cables having adequate section (minimum section 4mm²).
- Fix the cables with the relevant blocking devices supplied.
- Protect cables from any possible damage.
BATTERY
- Lead-acid batteries shall be positioned in a well ventilated place.
- Use only 12V
rechargeable lead batteries (capacity >40Ah).
Warning:
- Do not use "not rechargeable" batteries.
- Exhausted batteries shall be disposed in accordance with existing environmental protection regulations.
157
110
140
power supply net.
safety switch can be easily reached.
Fig.2 - VERTICAL INSTALLATION