REF:
Absolute reference point for the
measuring system. This value is de-
termined by calibrating the system
according to chapter 9.
DEC.:
Decimal point: modification of the
decimal point position to determi-
ne the resolution, eg. after pro-
gramming the calculation factor. Up
to 5 digits after the comma are pos-
sible.
DIR:
Direction: counting direction of the
measuring system
"UP"
upward
"DOWN"
downward
P KEY:
Time for which P-key needs to be
pressed to enter the programming
mode.
RESET:
Reset enable: reset to reference va-
lue via key
"ON"
Reset function on
"OFF"
Reset function off
ABS/REL:
incremental measurement enable.
"ON"
function on
"OFF"
function off
REF.EN.:
Ref. value input enable:
to enter / change calibration value.
"ON"
Reference value change on
"OFF"
Reference value change off
UNITS:
Unit of measure selection.
BRIGHT.:
LED display brightness toggle.
BAUD:
Baud rate: interface's baud rate.
LANGUAGE: Language: To choose the language
displayed
"GER"
German
"ENG"
English
CONTROL:
Nur für Servicezwecke
CALIBR.:
Fine calibration of the sensor. Only
has to be carried out before the
first use of the system or if system
components are exchanged.
10
MA100/1
.
Datum 31.03.2003
Art.Nr. 79918
9. Input mode
Reset function via keyboard
• Press key
to set the display to the reference
value.
Precondition: Parameter 'Reset enable' (RESET) in
programming mode must be programmed to "ON",
but unit must not be left in programming mode (see
chapter 7 'To leave programming mode').
Reset function via reference input
By short activation (ground switching) of the
input RESET eg. by a push button or by using a
proximity switch. (Closing contact function)
Incremental measurement
Press key
for activation.
• The display is zeroed.
• Sign blinks.
• Press key
to deactivate. The absolute measu-
ring value is displayed again.
Precondition: Menu point 'Incremental measure-
ment enable' (ABS/REL) in programming mode must
be programmed to "ON", but unit must not be left
in programming mode (see chapter 7 ‚'To leave
programming mode').
Reference value modification
For reference value alteration, keys
pressed simultaneously.
The display then shows the reference value, which
can be changed via the two arrow keys.
Press key
to store the new value.
MA100/1 returns to display mode, if
pressed.
Precondition: In programming mode menu points
'Reference value input enable' (REF.EN.) respective-
ly must be programmed to "ON", but unit must not
be left in programming mode (see chapter 7 ‚'To
leave programming mode').
Display during input mode
1
2
3
4
5
6
7
-
1
7
.
9
No.Digit
Significance
1
sign (blinking during 'incremental
measurement')
2 - 9
mearuing value
11 - 12
unit of measure
Z.Nr. 8664079
+
must be
key is
8
9
10 11 12
digit
1
3
m
m
display
Änd.Stand 118/03