4
Getting started
4.1
Assembly
Attach the wind speed alarm controller where desired. The dimensions can be taken from the
assembly drawing below.
4.2
Power supply
Establish power supply by means of the relevant connections and set up the connection of the
relay outputs to your system or signalling device (see 3.2). Make sure that the polarity and the
power supply is correct.
ATTENTION: Excessive voltage can destroy the device! Ensure zero voltage when
establishing the connection!
The device will power on immediately when connected to the power supply. The current reading
will be displayed when a sensor has been connected. If no sensor has been attached, the display
will show "00,0" if you have one of the PCE-WSAC 50-A2C versions (signal input 0...10 V) or.
"Err" if you have a PCE-WSAC 50-A1C version (Signal input 4...20 mA).
© PCE Instruments
16