Herunterladen Diese Seite drucken

dirna Bergstrom bycool compact TRP Diagnose Bei Ausfällen Seite 19

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

COMPACT
• Repair possible obstruction of the centrifugal blower or condenser fan; If the error
persists, replace the centrifugal blower or condenser fan (to access the blower or
fan it is necessary to remove the outer cover of the device, and the evaporator
cover for the centrifugal blower).
• Replace the 7.5A fuse. To access the condenser fan or blower fuses, it is necessary
to take down the control panel access cover in the interior air distribution panel.
• Replace the electronic control (to do this, first take down the control panel access
cover in the interior air distribution panel).
!
(If the error persists contact an Authorised Service Centre).
• Connect terminals of the control module correctly. (According to electrical
diagram attached).
• Replace electronic module/s on the compressor/s.
• Replace compressor/s.
• Check pressure (from 6 bars the compressors switch off), if necessary recover
gas and reload 250 grams per circuit.
!
To access compressors, electronic modules of compressor or charging jacks
you must remove the device's outer cover.
!
(If the error persists contact an Authorised Service Centre).
• Reprogramme the remote control.
• Replace the remote control's battery and reprogramme.
• Replace the electronic control (to do this, first take down the control panel access
cover in the interior air distribution panel).
• Replace the remote control.
!
(If the error persists, contact the Authorised Technical Service).
Solution