Herunterladen Diese Seite drucken

dirna Bergstrom bycool compact TRP Diagnose Bei Ausfällen Seite 17

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

COMPACT
• Connect or replace the power cable fuse.
• Replace the electronic control (to do this, first take down the control panel access
cover in the interior air distribution panel).
• Check and correct possible bad contacts, breakages or disconnection of the
power cable.
• Connect or replace the electronic control power fuse (to do this, first take down
the control panel access cover in the interior air distribution panel).
• Check and correct the position of the connection cables to power supply (Az with
fuse 25A a + and M a -).
!
(If the error persists contact an Authorised Service Centre).
• Check and correct possible bad contacts on terminals or cables of the return air
probe.
• Connect or replace return air probe.
!
(If the error persists contact an Authorised Service Centre).
• Check and correct any possible poor contacts in connections or terminals of the
power cable.
• Charge or replace the battery.
!
(If the error persists, contact the Authorised Technical Service).
Solution
17