1. DESCRIPTION
1. 1 APPLICATION
The wired alarm box reproduces the alarm signal from the control keypad (Sanicom® 1) or the remote control box
(Sanicom® 2).
1.2 DIMENSIONS
1.3 TECHNICAL DATA
• IP 2X
• For Sanicom® 1 (card AC121XXX) : 12 V power supply
• For Sanicom® 2 (card MOT120XXX) : 12 V power supply
1.4 SCOPE OF SUPPLY
Alarm box, 5 m alarm cable with cable gland, 1 male plug housing (Sanicom® 2)
2. INSTALLATION
Disconnect the lifting station electrically before any work is carried out.
SANICOM® 1 : CONNECTION TO THE INTEGRATED CONTROL PANEL
Unscrew the 2 screws of the integrated keypad using a Torx size 20 screwdriver. Lift the cover.
Remove the electronic board from its slot by gently pulling it out and check that it has the reference AC121XXX: this gua-
rantees the compatibility of the alarm box with the lifting station.
NOTE
A base board AC121XXX is only compatible with an alarm board AC121172.
A base board AC120XXX or MOT 120XXX is not compatible with an alarm board AC121172.
Using a flat screwdriver, remove the pre-cut pad located on the keypad cover.
Screw the cable gland on the cover; the cable must not move.
Push the quick-disconnect terminals into the intended slots on the electronic board, in any direction:
Put the electronic board back in its slot.
Replace the keypad cover and replace the screws.
Connect the other end (jack plug) to the wired alarm box.
Sanicom®
Switch the
device back on.
SANICOM® 2: CONNECTION TO THE REMOTE CONTROL BOX
Unscrew the Phillips-head screw on the top of the control box. Press the lugs on each side and pull the cover towards you.
Pull the electronic board out of its slot a little bit by gently pulling it out and check that it has the reference MOT120XXX on
it: this guarantees the compatibility of the alarm box with the lifting station.
NOTE
A base board MOT120XXX is only compatible with an alarm board MOT120172.
A base board AC120XXX or AC121XXX is not compatible with an alarm board MOT120172.
Using a flat screwdriver, remove the pre-cut pad located on the underside of the control box.
Screw the cable gland onto the cover; the cable must not move.