Herunterladen Diese Seite drucken

Siemens ER326BB70E Gebrauchsanweisung Seite 13

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 15
Maintenance
Faults
Fault
The general electrical
system is
malfunctioning.
The automatic switching
on function does not
work.
The burner flame is not
uniform.
The gas flow is not
normal or there is no
gas.
The kitchen smells of
gas.
14
Always clean off any liquid as soon as it is spilt: you will
save yourself any unnecessary effort.
Grains of sand that may come from cleaning fruits and
vegetables will scratch the glass surface.
Melted sugar, or foods which contain a lot of sugar which
may have spilt, should be cleaned off the hotplate
immediately, using the glass scraper.
Sometimes certain faults detected can be easily resolved.
Before calling the Technical Assistance Service, bear in
mind the following advice:
Possible cause
Defective fuse.
The automatic safety switch or circuit
breaker has tripped.
There may be food or cleaning products
stuck between the ignition sparkers and
the burners.
The burners are wet.
The burner caps are not correctly positioned. Check that the covers are correctly positioned.
The appliance is not earthed, is poorly
connected or the earthing is faulty.
The burner components are not correctly
positioned.
The grooves on the burner are dirty.
The gas supply is blocked via intermediary
valves.
If the gas is supplied from a gas cylinder,
check that this is not empty.
A gas tap has been left on.
Incorrect coupling of gas cylinder.
Possible gas leak.
Solution
Check the fuse in the main fuse box and
change it if it is damaged.
Check the main control panel to see if the
automatic safety switch or circuit breaker
has tripped.
The space between the ignition sparker and
the burner must be clean.
Dry the burner caps carefully.
Contact the installation technician.
Correctly place the parts on the appropriate
burner.
Clean the grooves on the burner.
Open all gas taps.
Change the gas cylinder.
Turn off the taps.
Check that the coupling is sound.
Shut off the gas supply, ventilate the premises
and immediately notify an authorised
installation technician so that they can check
and certify the installation. Do not use the
appliance until you are sure that there is no gas
leak in the installation or appliance itself.

Werbung