Never touch the power cord/plug or EV cable
with wet hands as this could cause a short
circuit or electric shock.
To avoid a risk of fire or electric shock, do not
use this device with an extension cord. If the
mains cable or EV cable is damaged it must
be replaced by the manufacturer, its service
agent, or similarly qualified persons in order to
avoid a hazard.
WALL MOUNTING WARNINGS
Read the instructions before mounting your
charging station on the wall.
Do not install the charging station on a ceiling
or inclined wall.
Use the specified wall mounting screws and
other accessories.
This unit is rated for indoor or outdoor
installation. If this unit is mounted outdoors,
the hardware for connecting the conduits to
the unit must be rated for outdoor installation
and be installed properly to maintain the
proper IP rating on the unit.
BASIC OPERATION - For Autostart
Models
VESTEL Electric Vehicle Charger (EVC) is
designed to charge plug-in electric vehicles (PHEV)
and battery electric vehicles (BEV) with Type 2
socket compatible cable on charging station side.
Please read important safety warnings and
instructions carefully before operating the EVC.
Button Functions
Button Light Color
Indications
Ready
Charging : Blinking Blue
Fault
Ventilation Required Mode:
Blinking Red
At the start-up, please be sure that Blue LED is on.
Connect the charging plug to the EV and then to the
EVC. VESTEL EVC starts the charging session au-
tomatically.
The charging plug is always locked to socket out-
let before starting to charge. The charging plug is
unlocked from socket outlet of VESTEL EVC after
disconnecting the charging cable from EV.
: Steady Blue
: Steady Red
English - 3 -
If the button LED is blinking red, your car needs
ventilation during charging because of the drivetrain
battery type. This EV charger unit is intended only
for charging electric vehicles not requiring ventilation
during charging.
If the LED is steady Red, please check troubleshoo-
ting section and do not connect any charging plug to
the VESTEL EVC.
BASIC OPERATION - RFID Equipped
Models
RFID equipped EVC has autostart functionality. If
no RFID master card is registered, it is used as au-
tostart EVC without RFID authorization. By default,
the product comes as autostart. If you want to use
the EVC with RFID authorization, please register an
RFID master card to the EVC. Check accessories
inside the package for master and slave RFID cards.
Your EVC comes with 1 master and 2 slave cards.
Find and take RFID master card in hand for further
steps.
a.Registering RFID Master Card
To be able to register RFID master card, you need to
reset local authorization list of the EVC. Switch your
EVC device off. For resetting EVC, please push the
button on the EVC for about 10 seconds while swit-
ching on the input power of the EVC. EVC will play
beep sound while reseting process. The first card
to be registered after the reset is set as the master
card. Now you have 20 seconds to register master
RFID card by tapping the master card to the RFID
reader on the EVC. Now you can use your master
card for registering user cards which will be used for
charging authorization.
b.Registering RFID User Cards
Master
Only registered RFID master card of the EVC can re-
gister and authenticate RFID user cards to the EVC.
Tap your RFID master card to the EVC. EVC plays
Master
User

Werbung