Congratulations,
You have just acquired an emergency power supply by SLAT, and we thank you for your choice.
This manual includes instructions for the installation, commissioning and maintenance of this equipment.
In order for the equipment to work properly, we recommend that these instructions be followed very carefully.
This equipment is designed to be connected to the 230 V public distribution network.
It ensures the continuity of service for the equipment in case of power failure.
A disconnect-switch or circuit-breaker shall be installed upstream according to standards.
To avoid electric shock, disconnect-switch or circuit-breaker must be open when commissioning or operating
maintenance.
The operation must be performed by qualified personnel only.
The battery is maintenance-free. Do not open it.
During installation, connect the ground wire first and disconnect it last when dismantling.
Respect orientation of the product (see chapter 2.1, page 16).
Provide sufficient convection (top / bottom clearance minimum 30 mm).
Size cables according to the maximum current input / output.
Observe the thermal and mechanical limits.
Battery to be connected is
Caution ! There is a risk of explosion if battery is replaced by wrong model.
When used, recycle product and battery according to instructions.
Internal use only.
EN 62368-1 conformity
Standards, directives and protection of the environment and public health
All products of the AES range are compliant with LV and EMC directives (immunity and emission). They are compliant with
standards:
EN 60950-1 (2006) + A11 (2009) + A1 (2010) + A12 (2011) + A2 (2013) (SELV class)
EN 61000-6-1(2007), EN 61000-6-2 (2005), EN 61000-6-3 (2007), EN 61000-6-4 (2007) + A1 (2011)
EN 50130-4 (2011)
EN 55022 (2006) + A1 (2007) class B
UL1950 for components.
They are also certified compliant with the following trade standards:
EN 54-4 (1997) + A1 (2002) + A2 (2006) : Fire detection and fire alarm systems. Part 4: power supply equipment.
EN 12101-10 class A (2005): Smoke and heat control systems. Part 10: power supplies.
NFS 61940 (2000) : Fire Safety Systems - Electrical power supplies as safety devices.
Some products (24V) are compliant with standards:
VdS 2541 (1996) : Energieversorgungseinrichtungen Anforderungen und Prüfmethoden.
VdS 2344 (2012) : Procedure for the testing, approval, certification and conformity assessment of products and
systems for fire protection and security technologies.
The DoP numbers and CE marking years are available on APPENDIX.
All certificates are available on our website:
SLAT is ISO 14001 certified since 2008.
SLAT manufactures all its products in accordance with RoHS and WEEE environmental directives.
SLAT recycles its products at the end of their service life through its recycling programme.
Good installation.
Safety precautions
VRLA type
.
(This equipment is not suitable for use in locations where children are likely to be present).
http://www.slat.com/en/services/documents/certificates/
13

Werbung

loading

Diese Anleitung auch für:

Aes 56 v