Herunterladen Inhalt Inhalt Diese Seite drucken

Installation / Fitting - BOMANN EBK 959 Bedienungsanleitung

Einbau- induktions- kochfeld
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Automatic switch-off
The automatic switch-off is a protective function for your appliance. If a stovetop is in operation for a long period and if you do not enter anything on the
control panel, the automatic switch-off will be activated. For the standard times of the different power settings, please refer to the following table:
Power setting
Shut-off time (Hours)
child lock
The appliance is equipped with a child lock to prevent children from turning on the appliance accidentally.
cAUTION:
• The stovetop has to be installed so that the heat can be dissipated. Air intake and outlet may not be blocked.
• The worktop, back walls, veneers, laminates, and adhesives used must be sufficiently heat-resistant (up to 100°C).
conditions for the installation location
• The appliance may only be installed on one side next to higher kitchen furniture, appliances, or walls.
• The appliance should not be installed directly next to refrigerators or freezers. Due to the heat dissipation, the energy consumption of the cooling
appliances will increase unnecessarily.
• At least 50 mm free space must remain under the entire cut-out for the appliance. Heat-sensitive objects (base cabinet, drawer, etc.) may not be
located in this area. Possibly existing side-walls or drawer cabinets must be cut out, or disassembled accordingly.
• The worktop must be at least 30 mm thick and at least 620 mm deep. It must lie horizontally and must be sealed off against overflowing liquids on
the wall side.
• The stovetop must be framed by a work surface of at least 50 mm on all sides.
• The cut-out may be 560 x 490 mm at maximum.
• The appliance must be installed so that sufficient air circulation is ensured (see Fig. 1 ).
A (mm)
760
Installation
NOTe:
Prior to sawing, stick a wide adhesive tape onto the outer edge of the cut-out to prevent jigsaw marks on the worktop.
• The worktop must be cut out in accordance with Fig. 2 .
16 16
1
2
3
8
8
8

Installation / Fitting

Fig. 1
B (mm)
c (mm)
min. 50
min. 20
Fig. 2
4
5
6
4
4
4
D
Air inlet
7
8
9
2
2
2
e
Air outlet 5 mm

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis