Technical manual
4 Mounting Guide
1) Prick/drill holes in the bottom of the cabinet (
2) Position DOL 278:
close enough to the climate computer for the rubber sleeve supplied (
between them (DOL 278 can be placed on either side of the climate computer).
so that there is enough space, particularly above DOL 278, for service setting (
lid.
3) Knock out large knock-out pieces (
rubber sleeve in one of the holes.
4) Tighten DOL 278 using Ø5 screws and, if necessary, Ø8 wall plugs (
sleeve is squeezed approx. 10 mm.
5) Mount the rubber sleeve (
6) Guide the cables through the rubber sleeve.
If space is inadequate right next to the climate computer, the rubber sleeve can be left out, and the
cables can be extended and routed through M25 screwed cable connections (
Figure 1: Mounting of DOL 278
5 Installation Guide
5.1 Electric Connection
In order to ensure max. security in case of an emergency situation, DOL 278 must not supply
24 VDC to products other than those stated by SKOV A/S.
If it does, any subsequent consequences will be at the owner's own risk.
The installation, service and troubleshooting in connection with electrical equipment must be
carried out by specialists in accordance with applicable national rules - in Europe in
accordance with EN 60204-1 and other applicable EU rules.
The installation of a supply isolator is required for each motor and power supply, so
maintenance of electrical equipment can be carried out in a dead environment. Supply
isolator is not supplied by SKOV A/S.
A
).
D
) from the climate computer and DOL 278 and mount the
) so that it is waterproof.
B
( F )
DOL 278 ON/OFF
E
), so that the rubber
).
F
( B )
( D )
( E )
15
B
) to fit neatly
C
) of the
( C )
( A )