Technical data
The accuracy relates to 1 year used in temperatures between 18
°C – 28 °C and 75% relative humidity. Further calibration is also
offered.
Max. voltage between the connection socket and ground:
600 V AC / DC
Fuses
Max. operating height:
Height of display:
Display
Polarity indicator
Overrange indicator:
Sampling rate
Low battery status:
Power supply
Operating temperature
Storage temperature
Dimensions
Weight
Category
F 200 mA self-resetting (maintenance
free)
F 10 A 1000 V quick-blow
2000 m above MSL
37 mm LCD
Max. 1999 (3½ )
Automatic
"1" is displayed
Approx. 0.4 sec.
Battery symbol is displayed
1 x 9 V block battery
0 °C to 40 °C
-10 °C to 50 °C
191 x 82 x 37 mm (without holster)
200 x 89 x 38 mm (with holster)
280 g incl. battery
CAT III 600 V