Herunterladen Diese Seite drucken

Berner 185139 Bedienungsanleitung Seite 41

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Diode test
With the selector switch set to "
into the 'COM' socket and the red test lead into the V/Ω/TEMP/CAP
socket. Using the test probes, touch the test points of the test
object. Red test lead = anode, black test lead = cathode. The
forward voltage drop is displayed.
Measurement
range
-Forward current: approx. 25 µA, reverse voltage: approx. 2.8 V.
Continuity testing
With the selector switch set to "
into the 'COM' socket and the red test lead into the V/Ω/TEMP/CAP
socket. Using the test probes, touch the test points of the test
circuit. An acoustic signal is emitted if a resistance under 70 Ω is
measured.
Important: Isolate from the power supply and discharge
capacitors in the circuit to be measured.
Measurement
range
-Measuring voltage: approx. 2.8 V.
◦))
/ ◦))". Insert the black test lead
Resolution
Display
1 mV
Forward voltage
/ ◦))". Insert the black test lead
Function
The integrated buzzer signals up to a
resistance of 70 Ω
40

Werbung

loading

Diese Anleitung auch für:

Multimeter 313