DC voltage measurement / V=
Use the selector switch to set the appropriate range. Insert the
black test lead into the 'COM' socket and the red test lead into the
V/Ω/TEMP/CAP socket. Using the test probes, touch the test points
of the test object. Read measurement value on the display. The
polarity of the voltage will also be displayed.
DC voltage
Measurement
range
200 mV
2 V
20 V
200 V
600 V
-Input resistance: 10 MΩ
Max. input voltage: 600 V DC
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
35
Accuracy
± 0.5 % of reading
+ 1 digits
± 0.5 % of reading
+ 3 digits
± 0.8 % of reading
+ 3 digits