Connecting the external high voltage on/off control signal
In order to switch the high voltage of the generator on/off via an external control refer to section
5.7 in the full manual.
The main screen
The LCD display provides information about the status of the generator. This information is
shown via texts and symbols.
Explanation of the symbols used:
Generator is operating in Voltage Control (VC) mode.
High voltage is switched on.
Keyboard is locked.
External on/off mode is enabled.
RunButton mode is enabled.
Key functions
The keys on the CM5 are defined as follows:
[ ]
Change the Voltage Setpoint.
[ ]
Change the Voltage Setpoint.
[◄]
Display the Setpoint values.
[►]
Display the Setpoint values.
Displaying the current Voltage Setpoint
Press the [◄] or [►] key. The set voltage and current limit are now shown on the display. The
set values are shown for as long as the key is depressed. After releasing the key the main
screen is displayed again after 2 seconds.
Changing the Voltage Setpoint
Note:
Avoid unnecessarily high output voltages, otherwise spark-over can occur on the
-
charging bars or electrodes. This will impair the reliability and proper functioning of
the charging process.
Press the [ ] / [ ] key. The currently set values will now be shown on the display. Press the
[ ] / [ ] key again to change the setpoint value. If the keys are not operated for longer than 2
seconds, the main screen is displayed again.
To raise/lower the setpoint more rapidly, press the [ ] / [ ] keys for longer. The longer the keys
are depressed, the faster the value changes. Also, the value initially changes in steps of 0.1 kV
and after a short time in steps of 1.0 kV.
CM5_QM_9752090135_NL_D_GB_F_IT_V2_2
The main screen of the generator shows the currently
measured voltage and current and also the operational
mode. Texts are shown on the left-hand side of the display
and symbols on the right-hand side. The symbols that refer to
an operational mode appear on the same line as the text.