Technical information / Functioning / Parameters
Window function
Technical data
Page 26
The window function enables the
monitoring of a defined accepta-
ble range. When the level varies
between the switch-on point
(SPx) and the switch-off point
(rPx), the output is switched (win-
dow function/NO) or not swit-
ched (window function/NC).
The width of the window can be
set by means of the difference
between SPx and rPx. SPx =
upper value, rPx = lower value.
Operating voltage [V] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 ... 30 DC
Current rating [mA]
Short-circuit protection; reverse polarity protection / overload protection
Voltage drop [V] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 2.5
Current consumption [mA] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 80
Accuracy of switch point [% of value of measuring range] . . . . . . . . . . ± 5
Repeatability [% of value of measuring range] . . . . . . . . . . . . . . . . . . . ± 2
Maximum speed of the change of level [mm/s]
- LKx022 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
- LKx023 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
- LKx024 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
Dielectric constant medium . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > 2
Maximum vessel pressure [bar] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5
Housing material . . . . . . . . . . . . . . . . .EPDM/X (Santoprene); FPM (Viton);
PC (Macrolon); PP (polypropylene)
Materials (wetted parts) . . . . . . . . . . . . . . . . . . . . . . . . .PP (polypropylene)
Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .IP 67, III
Operating temperature [°C] . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 ... +60
Medium temperature [°C]
- Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0...+65
- Coolant emulsions, water and hydrous media*
- LKx022 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 ... +65
- LKx023 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 ... +60
- LKx024 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 ... +55
Storage temperature [°C] . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-25 ... +80
Shock resistance [g] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Vibration resistance [g] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5
EMC
EN 61000/4/2 ESD: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4/8 kV
EN 61000/4/3 HF radiated:
EN 61000/4/4 Burst:
EN 61000/4/5 Surge: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500 V /1 kV
EN 61000/4/6 HF conducted: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 V
*For water and hydrous media with temperatures > 35°C install the unit into
a climatic tube (order no. E43100, E43101, E43102).
P
SP
rP
1
0
1
0
(when mounted with mounting accessories)
Optalloy-plated brass; NBR (Buna N); PA; Pocan;
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 V/m
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 kV
acceptable range