Herunterladen Diese Seite drucken

RIB AA30091 Bedienungsanleitung Seite 33

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 38
confirm the deleted entry. Subsequently, programming two-tone led DL10 flashes red for
10 seconds, and you can enter new codes as shown in the following procedures.
4 - Reset DIP 1 to OFF and DIP 2 to OFF.
5 - End of sequence.
RADIO CODE MEMORY FULL SIGNAL
The signal will only be given when the gate is at a standstill.
1 - First, set DIP 1 to ON and then DIP 2 to ON.
2- Led DL10 flashes green 6 times to signal that the memory is full (1000 codes saved).
Subsequently, programming two-tone led DL10 flashes red for 10 seconds, allowing (if
necessary) to delete all the codes.
4 - Reset DIP 1 to OFF and DIP 2 to OFF.
5 - End of sequence.
G - PEDESTRIAN OPENING RADIO CODES PROGRAMMING (MAX 1000
CODES)
The codes can be programmed only when the gate is at a standstill.
1 - First, set DIP 1 to ON and then DIP 3 to ON. Programming two-colour led DL10 flashes
green for 10 seconds.
2 - Press the remote control button (normally channel B) within the pre-set 10 seconds. If the
remote control has been saved correctly, two-tone led DL1 turns red for an instant, and
a buzzer tone confirms the saved entry. The 10 seconds for programming the codes are
reset automatically with two-tone led DL10 that flashes green to save the next remote
control.
3 - To finish programming, let the 10 sec pass or press briefly the PROG. button.
Programming led DL10 stops flashing.
4 - Reset DIP 1 to OFF and DIP 3 to OFF.
5 - End of sequence.
DELETING ALL RADIO CODES RESERVED TO PEDESTRIAN OPENING
The codes can be deleted only when the gate is at a standstill.
1 - First, set DIP 1 to ON and then DIP 3 to ON. Programming led DL10 flashes green for
10 seconds.
2 - Within these 10 seconds, press and hold the PROG button for 5 seconds. Code deletion
is indicated by two red flashes of the two-tone led DL10 and 2 tones of the buzzer to
confirm the deleted entry.
3 - Subsequently, programming two-tone led DL10 flashes green steady for 10 seconds, and
you can enter new codes as shown in the following procedures.
4 - Reset DIP 1 to OFF and DIP 3 to OFF.
5 - End of sequence.
RADIO CODE MEMORY FULL SIGNAL
The signal will only be given when the gate is at a standstill.
1 - First, set DIP 1 to ON and then DIP 3 to ON.
2 - Led DL10 flashes green 6 times to signal that the memory is full (1000 codes saved).
Subsequently, programming two-tone led DL10 flashes red steady for 10 seconds,
allowing (if necessary) to delete all the codes.
3 - Reset DIP 1 to OFF and DIP 3 to OFF.
4 - End of sequence.
OPERATION OF CONTROL ACCESSORIES
OPENING BUTTON (COM-OPEN)
When the gate is at a standstill, the button controls the opening movement. If pressed during
closing, the gate will re-open.
CLOSING BUTTON (COM-CLOSE)
When the gate is at a standstill, the button controls the closing movement.
SINGLE CONTROL BUTTON (COM-K BUT)
If DIP 6 is set to OFF = > it runs a command sequence open-stop-close-stop-open etc.
If DIP 6 is set to ON = > it opens the closed gate. If operated while the gate is opening, the
button has no effect. If operated with the gate open, it closes the
gate. If operated while the gate is closing, it re-opens the gate.
REMOTE CONTROL FOR BOTH FULL AND PEDESTRIAN OPENING
If DIP 6 is set to OFF = > it runs a cyclical command sequence open-stop-close-stop-open
etc.
If DIP 6 is set to ON = > it opens the closed gate. If operated while the gate is opening, the
button has no effect. If operated with the gate open, it closes the
gate. If operated while the gate is closing, it re-opens the gate.
CLOCK FUNCTION - B.I.O. CONTROL (COM-B.I.O.)
The clock function is useful during rush hours, when vehicle traffic is slow (e.g. entrance/exit
of workers, emergencies in residential areas, parking lots, etc.).
ENABLING THE CLOCK FUNCTION
By connecting a switch and/or a daily/weekly clock to the "COM-B.I.O." terminals, you can
open the gate (and keep it open) until the switch or clock remain enabled.
All command functions are inhibited with open automation.
When releasing the switch, or once the set time has lapsed, the automation will shut down
instantly.
PEDESTRIAN OPENING BUTTON (COM-PED.BUT)
Command reserved to partial opening and re-closing of the gate.
When opening, closing or pausing the pedestrian command, you can control the full opening
using any command connected on the board.
Using the DIP switches 6, you can choose the operating mode of the pedestrian control
button.
If DIP 6 is set to OFF = > it runs a cyclical command sequence open-stop-close-stop etc.
If DIP 6 is set to ON = > it opens the closed gate. If operated while the gate is opening, the
button has no effect. If operated with the gate open in pedestrian
mode, it closes the gate. If operated while the gate is closing, it
re-opens the gate.
FULL OR PEDESTRIAN AUTOMATIC CLOSING TRIMMER (TCA) - Not enabled by default
and led DL3 off (trimmer rotated fully counter-clockwise).
With this trimmer it is possible to adjust the time before the full or pedestrian automatic
closing.
The gate can be closed automatically only with the door open, by operating the full or
pedestrian control and with led DL3 on (trimmer rotated clockwise to enable the function).
Once the gate has been fully opened the pause time can be adjusted from a minimum of 2
seconds to a maximum of 2 minutes.
Once the gate has performed the pedestrian opening, the pause time can be adjusted from
2 seconds till a maximum of 30 seconds.
This time setting before the automatic closing can be done by adjusting the TCA trimmer and
will be in relation to its position.
For instance, with the trimmer positioned half way, the pause time after the complete open
postion would be 1 minute, whilst it will be 15 seconds after the pedestrian opening.
MANUAL RELEASE (LED DL4)
The position of the unlocking lever is controlled electronically, so if you unlock the operator,
the micro-switch contact will open (led DL4 turns off) and the controls are not enabled.
When you reposition the release lever, and after running a command, the first
movement will take place at slow speed. Only after completing this first movement,
the operator will resume work at the set speed.
OPERATION AFTER BLACK-OUT
At the time of the blackout, gate status is saved in the memory.
When mains voltage is restored:
If the gate is located on the opening or closing limit switch, operating the control will close
or open the gate with the saved data.
If the gate is in intermediate position, operating the control will open the gate slowly until
it reaches the opening limit switch. After completing this first movement, the operator will
resume work at the set speed.
OPERATION OF SAFETY DEVICES
PHOTOCELL (COM-PHOT) - Safety function SF2 - PL "b" according to EN13849-1
With the photocell enabled, the buzzer emits 1 tone.
DIP 4 OFF = > with gate closed, if an obstacle stops the photocell beam, even if an opening
command is given, the gate does not open. During operation, the photocells
intervene both during opening (with the gate opening only after freeing the
photocell beam), and closing (with reverse motion recovery only after freeing
the photocell beam).
DIP 4 ON = > with the gate closed, if an obstacle is in front of the photocell beam and
the control to open the gate is operated, the gate opens (during opening
the photocells will not intervene). The photocells will intervene only during
closing (with the gate opening after 1 second, even if the photocells are still
engaged).
IMMEDIATE GATE CLOSURE AFTER TRANSIT ON PHOTOCELLS
DIP 8 ON and DIP 4 OFF = > while the gate opens, passing in front of the photocells, the
33
G
B

Werbung

loading

Diese Anleitung auch für:

K800 24vAa30093