Status displays
The LED at the BSG is usedfor system status display:
LED flashes evenly
(system run-up)
LED flashes long on, short off,
(own BSG address incorrect)
LED flashes long on, short off,
short on, short off, long on...
(more than 31 users on the line)
LED flashes short on, long off...
(programming mode active)
LED always on
(BSG address error at other BSGs)
Commissioning and
programming procedure
As commissioning involves alternate-
ly pressing buttons at the door loud-
speaker and various actions at the
BT itself, commissioning must be
performed by 2 people.
Remark:
Ensure:
• that the call buttons of all the
door loudspeakers are inscribed to
allow the individual call buttons to
be assigned also to the correspon-
ding BT.
• that each BSG 650-... has its own
address set.
• that all units are connected to the
mains.
• that in systems with more than
one line, one bus supply unit
BVG 650-... is installed.
Important
In systems with more than one
BSG 650-... connected together with
one BVG 650-..., if the programming
button on one BSG is pressed - all
other connected BSG's will be
switched to the programming mode.
In the programming mode, only one
door loudspeaker may be active at
any one time, i.e. door loudspeakers
0,3s
0,3s
0,3s
0,3s
0,3s
0,3s
2s
2s
2s
0,3s
cannot be programmed simultane-
ously.
Programming the call
buttons at the bus door
loudspeaker
Commissioning
Setting the address
The BSG 650-..., and each BSG
where there are several in the
system, must be given its own
address. Any address from 1-9 and
A-F can be set. "0" is not admis-
sible as an address!
230 V AC ok?
yes
Check status displays!
Program in accordance with Figs.
2 - 14 / 21 in sequence. Repeat steps
6 -14/21 and 22 if required, and
after Figs. 23 and 24 terminate the
programming process.
Parallel operation
For programming, see Figs. 15 - 21.
For checking, see Figs. 11 - 14.
In the case of a door call, the call
signal sounds at both BTs.
Whichever of the two BTs takes the
call then has a speech connection to
the calling door. The second BT
cannot break into the call.
0,3s
0,3s
0,3s
0,3s
0,3s
0,3s
0,3s
2s
0,3s
0,3s
0,3s
2s
0,3s
Defining the calling tone from
the BTLM/BTLE
It is possible to choose between two
call types. Define which tone
sequence you wish to sound at all
BTs in case of a door call from this
BTLM 650-... .
In the programming mode and
when the BTLM is active, it is
possible to change between the two
tone types for three seconds by
pressing the light-/programming-
button at the active BTLM/BTLE.
This definition can be made
subsequently, but is always binding
for all calls from this BTLM.
Note!
If an already programmed door
button is pressed for longer than
3 secs in the programming mode at
the active door loudspeaker, first a
warning tone sounds and then the
confirmation tone. This call button is
subsequently deleted. However, if a
BT is active at this moment, this
button is overwritten by the new
address.
Exchange instructions
Exchanging system users
If a programmed system user is
removed from the line and then
reconnected, the programming is
0,3s
0,3s
0,3s
etc.
etc.
2s
etc.
0,3s
etc.
5