64
Test results
(the acceptance test is described on page 49.)
Test
Visual check
Wiring loom and wiring layout: No kinks or crimping
Component boards: Printed circuit boards and connectors plugged in
correctlyt
Lamps inserted correctly
Paintwork (no scratches or the like)
All covers fitted
High voltage
High voltage basic insulation test 1.25 kV AC/2.5 kV DC
Earthing
Earthing test: Value < 0.1 Ω
Functional test
Main supply correct
Canopy accent lighting working
Operating panel: Keys and display
Fan run-on (equipment cooling) at least 3 minutes
Canopy safety loop OK
Current consumption L1 < 14A
Current consumption L2 < 14A
Current consumption L3 < 14A
Handover
Hand over accessories to the customer (see page 53)
Start/Stop: UV lamps on and off,
Reset Cancel selected tanning time
Body cooling: Stage switching, on and off
Facial tanner: on and off
Result OK?
Unit
Value
yes
no
–
yes
no
–
–
yes
no
–
yes
no
–
yes
no
–
yes
no
yes
no
–
yes
no
–
–
yes
no
yes
no
yes
no
–
yes
no
yes
no
yes
no
–
yes
no
–
A
A
A
–
yes
no
–
–
–
–
–
–
–
–
–
–
–
–
–