Acceptance testing
one minute. It will then be approximately another minute before full
power is reached again.
– With the Ergoline Ambition 250: Check the accent lighting in the can-
opy.
– Check whether all UV low pressure lamps in the canopy and base are
working.
Functional test with internal time switching
– Set the time using the
key on the operating panel of the tanning
device and then use the reset key to revert to 0 again.
– Set the time using the
key on the operating panel of the tanning
device and start the device with the
– Press the
key on the operating panel of the tanning device and
check whether the UV lamps go off and come on again if the key is
pressed once more.
– Use the fan key on the operating panel of the tanning device to run
through the body cooling stages (stage 1, stage 2, off).
– When the device has been running for at least 1 minute: Switch off
the facial tanner. Switch the facial tanner on again after waiting for
one minute. It will then be approximately another minute before full
power is reached again.
– With the Ergoline Ambition 250: Check the accent lighting in the can-
opy.
– Check whether all UV low pressure lamps in the canopy and base are
working.
Checking the phase splitting
L1 current
L2 current
L3 current
Checking fan run-on
– Switch off the device using the token equipment or the operating pan-
– Check whether the device fan runs on for 3 minutes.
key.
Checking the fault loop in the canopy.
– Check the fault loop by activating the individual components:
End of test/handover
– Sign the test report.
– Handing over the accessories to the operator:
Ambition 250
< 14 A
< 14 A
< 14 A
el.
Filter disk (3 x)
Lamp cover in canopy
Operating instructions
2 pairs of UV protective goggles
Suction cup
4 mm Allen key
XS-35
< 14 A
< 14 A
< 14 A
53