Contents Contents About This Manual ............... 7 Scope.................. 7 Validity ................7 Cautions and Notes ............7 Safety Instructions ............... 8 Description ................... 9 Application ................9 System Overview .............. 10 Product Range ..............11 3.3.1 Part Numbers............11 3.3.2 Chassis ...............
Seite 4
Draco vario ultra DisplayPort KVM Extender 3.6.13 Model L- / R474-BXE .......... 25 3.6.14 Model L- / R474-BUE .......... 25 3.6.15 Model L- / R474-BXE2 ........26 3.6.16 Model L- / R474-BAX / -BSX....... 26 3.6.17 Model L- / R474-BAP .......... 26 3.6.18 Model L- / R474-BBX ..........
Seite 5
Contents Command Mode ............... 47 USB-HID Ghosting ............49 Configuration File .............. 50 5.5.1 Parameters for CPU Units........50 5.5.2 Parameters for CON Units ........52 5.5.3 Parameters for CPU und CON Units....53 Operation ..................54 Download of DDC Information .......... 54 Parallel Operation of redundant CPU Units.......
Seite 6
CE Declaration Of Conformity........... 82 10.2 North American Regulatory Compliance ......83 10.3 Product Safety ..............83 10.4 WEEE ................84 10.5 RoHS/RoHS 2..............84 Glossary..................85 Pos: 1 /806-IHSE/Zu diesem Handbuch/ATB_Zu diesem Handbuch @ 5\mod_1278573163276_6.doc @ 41510 @ 1222 @ 1 2017-06-06...
This symbol indicates important information to help you make the best use of this product. This symbol indicates best practice information to show recommended and optimal ways to use this product in an efficient way. Pos: 2 /806-IHSE/Sicherheitshinweise/ATB_Sicherheitshinweise @ 5\mod_1278573321245_6.doc @ 41528 @ 1 @ 1 2017-06-06...
Do not attempt to open or repair the KVM Extender. There are no user serviceable parts inside. Please contact your dealer or manufacturer if there is a fault. Pos: 3 /806-IHSE/Beschreibung/UEB_Beschreibung @ 5\mod_1278573379151_6.doc @ 41546 @ 1 @ 1 2017-06-06...
The KVM Extender with fiber interconnect cables can also be used with applications in environments which are subject to electromagnetic interference. Electromagnetic interference can limit the maximum distance and reliability of operation. Pos: 5 /806-IHSE/Beschreibung/System-Übersicht /474-xx @ 6\mod_1304579735410_6.doc @ 50803 @ 2 @ 1 2017-06-06...
KVM Extender CON Unit Console (monitor, keyboard, mouse) Second monitor (option, only with Dual-Head devices) USB-HID devices (option, only with 4x USB-HID devices) See Chapter 4.3, Page 43 for installation examples. Pos: 6 /806-IHSE/Beschreibung/Gerätetypen/493-xx @ 17\mod_1495093811609_6.doc @ 184943 @ 233333 @ 1 2017-06-06...
Description Product Range 3.3.1 Part Numbers Part numbers for Connections via Cat X or Fiber Cable All devices are available in the following versions: Connection via Cat X cable (x = "C") Connection via Single-mode fiber cable (x = "S") ...
Draco vario ultra DisplayPort KVM Extender 3.3.2 Chassis Model Description 474-BODY2 Empty chassis for up to 2 boards, 1x external power supply unit 474-BODY2R Empty chassis for up to 2 boards, 1x external power supply unit, preparation for redundancy for a second power supply unit (external) 474-BODY2N Empty chassis for up to 2 boards, 1x internal power...
Description 3.3.4 Upgrade Modules Model Description L474-BXH Upgrade module with 2x USB-HID R474-BXH L474-BXE Upgrade module with 2x USB 2.0 R474-BXE L474-BXE2 Upgrade module with 2x USB 2.0 R474-BXE2 L474-BAX Upgrade module with Analog Audio / Serial RS232 (bidirectional) R474-BAX Upgrade module with balanced analog Audio L474-BBX (unidirectional)
USB 2.0 upgrade module with 4x USB 2.0 and L474-BXExR redundant connector for interconnect cables, plug and R474-BXExR play (based on: ICRON 2300 Core) Pos: 7 /806-IHSE/Beschreibung/Überwachungsmodule/474-xx @ 14\mod_1415202166328_6.doc @ 157997 @ 3 @ 1 3.3.6 Monitoring Modules Model Description...
KVM Extenders and the power supply units can get warm and must not be installed in closed rooms with no air circulation. For rack-mount installations, at least 0.5 U (height unit) is required above the extenders for ventilation. Pos: 9 /806-IHSE/Beschreibung/Zubehör/483-xx @ 13\mod_1412172273934_6.doc @ 151737 @ 2 @ 1 2017-06-06...
For operation with three KVM Extender CON modules and a USB 2.0 CON module in a 4-fold vario chassis, two power supplies are necessary. In this case, redundancy is inapplicable. Pos: 14 /806-IHSE/Beschreibung/Geräteansichten/474-xx/6-fach Vario-Gehäuse 474-BODY6R @ 6\mod_1304580442488_6.doc @ 50894 @ 3 @ 1 2017-06-06...
The 6-fold vario chassis is not equipped with a fuse on its primary side. Therefore the protection against excessive currents has to be provided by the electrical installation of the building. Pos: 15 /806-IHSE/Beschreibung/Geräteansichten/481-xx/6-fach Vario-Gehäuse 474-BODY6BP @ 9\mod_1367827188730_6.doc @ 71694 @ 3 @ 1 2017-06-06...
Slot for modules #3 Slot for modules #1 Connect to power supply 1 Connect to power supply 2 (redundancy) Slot for modules #6 Slot for modules #4 Slot for modules #2 Pos: 17 /806-IHSE/zz_Layout/Seitenumbruch @ 8\mod_1348581820516_0.doc @ 69462 @ @ 1 2017-06-06...
Draco vario ultra DisplayPort KVM Extender Pos: 18 /806-IHSE/Beschreibung/Geräteansichten/474-xx/21-fach Vario-Gehäuse 474-BODY21R @ 8\mod_1348579151346_6.doc @ 69400 @ 3 @ 1 3.6.7 21-fold Vario Chassis 474-BODY21R CPU and CON Unit Rear View Slots for modules #1 - #21 Front View Connect to power supply 2...
To CPU: USB 2.0 Connect to USB 2.0 devices Connect to USB 2.0 devices Pos: 29 /806-IHSE/Beschreibung/Geräteansichten/474-xx/Typ L- / R474-BAX / -BSX @ 6\mod_1304583540285_6.doc @ 51002 @ 3 @ 1 3.6.16 Model L- / R474-BAX / -BSX CPU Module CON Module...
The CPU module with balanced audio can be also used on top of an extender CON Unit. It depends on the purpose of use. Pos: 32 /806-IHSE/Beschreibung/Geräteansichten/474-xx/Typ L- / R474-BDX @ 6\mod_1304583577801_6.doc @ 51020 @ 3 @ 1 3.6.19 Model L- / R474-BDX...
Connect to interconnect cable 2 To CPU: USB 2.0 Connect to USB 2.0 devices Connect to USB 2.0 devices Pos: 38 /806-IHSE/Beschreibung/Geräteansichten/474-xx/Typ L- / R474-BXES @ 15\mod_1455284047251_6.doc @ 165845 @ 3 @ 1 3.6.24 Model L- / R474-BXES CPU Module CON Module...
Connect to USB 2.0 devices Connect to USB 2.0 devices Only one USB 2.0 CON module may be installed per chassis. Pos: 40 /806-IHSE/Beschreibung/Geräteansichten/483-xx/Typ 474-SNMP @ 13\mod_1412172938631_6.doc @ 151898 @ 3 @ 1 3.6.26 Model 474-SNMP Control Unit Rear View...
Device ready Connection and USB signal (interconnect) available Violet Green Connection and video signal available Connection, USB and video signal available Light Blue (operating status) Pos: 44 /806-IHSE/Beschreibung/Diagnose LEDs/474-xx/Diagnose Zusatzmodul Digital-Audio @ 6\mod_1304584173301_6.doc @ 51201 @ 3 @ 1 2017-06-06...
Static: CPU Unit: AES/EBU signal (Mini-XLR) available Flashing: CPU Unit: Digital noise Static: CPU Unit: S/PDIF signal (TOSLINK) Blue available Flashing: CPU Unit: Digital noise Green CON Unit: Signal available Pos: 45 /806-IHSE/Beschreibung/Diagnose LEDs/474-xx/Diagnose Zusatzmodul USB-HID @ 6\mod_1304584220145_6.doc @ 51219 @ 3 @ 1 2017-06-06...
CON Unit: Keyboard in command mode Flashing CON Unit: KVM Extender in command slowly mode or no connection Flashing Operating status fast Pos: 46 /806-IHSE/Beschreibung/Diagnose LEDs/474-xx/Diagnose Zusatzmodul USB 2.0 embedded @ 7\mod_1331803265129_6.doc @ 58231 @ 3 @ 1 2017-06-06...
CPU) available USB 2.0 device(s) connected Status LED No connection between CON and CPU (green) module Connection between CON and CPU module available Pos: 47 /806-IHSE/Beschreibung/Diagnose LEDs/474-xx/Diagnose Zusatzmodul USB 2.0 V1 @ 6\mod_1304584254816_6.doc @ 51237 @ 3 @ 1 2017-06-06...
Only connection available, no USB 2.0 signal Green / Connection available, no USB 2.0 device light blue connected flashing Light blue Connection and USB 2.0 signal available (operating status) Pos: 48 /806-IHSE/Beschreibung/Diagnose LEDs/474-xx/Diagnose Zusatzmodul USB 2.0 V2 @ 15\mod_1455286194876_6.doc @ 165945 @ 3 @ 1 2017-06-06...
Draco vario ultra DisplayPort KVM Extender 3.7.6 Status Upgrade Module USB 2.0 V2 The upgrade module USB 2.0 is fitted with a multi color LED on both sides for overall status indication and with two further LEDs on the back side for indication of the connection status.
Seite 37
Description Device ready, no Matrix connection Violet Connection to Matrix available Green USB 1.1 connection available Light Blue USB 2.0 connection available Blue Debug mode Pos: 49 /806-IHSE/Beschreibung/Diagnose LEDs/483-xx/Diagnose Überwachungsmodul SNMP @ 13\mod_1412177197177_6.doc @ 151963 @ 3 @ 1 2017-06-06...
Link status Port not activated (orange) Flashing Port activated, no connection via network cable Link status Port not activated (green) Flashing Port activated, no connection via network cable Pos: 50 /806-IHSE/Installation/UEB_Installation @ 5\mod_1278574971589_6.doc @ 41768 @ 1 @ 1 2017-06-06...
Installation Installation Pos: 51 /806-IHSE/Installation/Lieferumfang prüfen/483-xx @ 13\mod_1412177615148_6.doc @ 151995 @ 2 @ 1 Package Contents Your extender package contains the following items: KVM Extender: KVM Extender pair (CPU Unit and CON Unit) in the vario chassis 1x (redundancy 2x) 5VDC international power supply unit per KVM Extender unit ...
USB cable (1.8 m, USB type A to type B) If anything is missing, contact your dealer. Pos: 52 /806-IHSE/Installation/System anschließen/483-xx @ 13\mod_1412177849132_6.doc @ 152027 @ 233 @ 1 System Setup First time users are recommended to setup the system with the CPU Unit and the CON Unit in the same room as a test setup.
Installation 4.2.1 KVM Extender Setup Switch off all devices. CON Unit Installation Connect your monitor(s), keyboard and mouse to the CON Unit. Connect the CON Unit with the interconnect cable(s). Connect the 5VDC power supply to the CON Unit. CPU Unit Installation Connect the source (computer, CPU) to the CPU Unit with the supplied cables.
Seite 42
USB 2.0 devices). Upgrade Module USB 2.0: Connect the CPU to the CPU Unit (USB 2.0). Connect the USB 2.0 devices to the CON Unit (Connect to USB 2.0 devices). Pos: 53 /806-IHSE/Installation/Installationsbeispiele/UEB_Installationsbeispiele @ 5\mod_1278581564870_6.doc @ 42759 @ 2 @ 1 2017-06-06...
Installation Example Applications This section illustrates typical installations of KVM Extenders: Pos: 54 /806-IHSE/Installation/Installationsbeispiele/477-xx_COMP @ 5\mod_1291124264328_6.doc @ 44767 @ @ 1 KVM Extender (Single-Head) KVM Extender (Single-Head with Digital / Analog Audio) 2017-06-06...
Seite 44
Second monitor (option, only with Dual-Head devices) USB 2.0 devices (option, only with 2x USB 2.0 devices) Audio sink (optional, only with devices with Analog Audio / Serial option or Digital Audio option) Pos: 55 /806-IHSE/Installation/Zusatzmodule/474-xx_Zusatzmodule @ 9\mod_1373960474835_6.doc @ 77366 @ 2 @ 1 2017-06-06...
Installation Overview Upgrade Modules This section illustrates an overview of the available types of upgrade modules for the KVM Extender. Overview Upgrade Modules Pos: 56 /806-IHSE/Konfiguration/UEB_Konfiguration @ 5\mod_1278575517073_6.doc @ 41846 @ 1 @ 1 2017-06-06...
Draco vario ultra DisplayPort KVM Extender Configuration Pos: 57 /806-IHSE/Konfiguration/Übertragungsparameter/492-xx @ 17\mod_1495013897064_6.doc @ 184868 @ 2 @ 1 Transmission Parameters The device operates with a manufacturer optimized compression method, the so-called Video-Codec Lici® (Lightweight Image Coding technology) of the Fraunhofer-Instituts (IIS). The transmission is handled visibly and up to mathematically lossless, at the same time without the loss of frames (no framedrops) and at low latency.
Delete the file called "DDC-EDID.bin" on the flash drive of the CPU Unit. By deleting this file, the factory DDC Information is restored. Pos: 59 /806-IHSE/Konfiguration/Kommando-Modus/474-xx @ 6\mod_1304585026863_6.doc @ 51291 @ 2 @ 1 Command Mode During normal use, the console keyboard functions in the usual manner.
Seite 48
In order to set a 'Hot Key' back to default settings of the extender, press the key combination <Right Shift> + <Del> within 5 s after plugging in a keyboard. Pos: 60 /806-IHSE/Konfiguration/USB-HID-Ghosting/K477_USB-HID-Ghosting @ 9\mod_1362404683851_6.doc @ 71192 @ 2 @ 1 2017-06-06...
(computer, CPU). When using a USB combo device as a USB-HID input device, switching to a CPU Unit with activated USB-HID Ghosting may cause limited functionality. Pos: 61 /806-IHSE/Konfiguration/474_Konfigurationsdatei/483-xx 493-xx-de @ 17\mod_1495099196680_6.doc @ 185115 @ 2333 @ 1 2017-06-06...
Draco vario ultra DisplayPort KVM Extender Configuration File The KVM Extender contains a configuration file (Config.txt) to set specific parameters and to read out device and video information. You can find it on the flash drive of the KVM Extender. The flash drive can be opened by a mini USB connection to a computer.
Seite 51
Configuration Compression Parameter Function MEDCPRATE Activate medium compression rate MINCPRATE Activate low compression rate MAXCPRATE Activate high compression rate ENADITHER Activate dithering filter for Mac OS systems Shared Operation Parameter Function KBDCON Activate Keyboard Connect (only with redundant CPU Units) Activate Mouse Connect (only with redundant MOUCON CPU Units)
Draco vario ultra DisplayPort KVM Extender 5.5.2 Parameters for CON Units You can write the following parameters into the configuration file of a CON Unit. Output Settings Parameter Function 1080p50Hz Always display 50 Hz when using 1920x1080 DISEXTOSD Deactivate extender OSD ENAFRAME Show orange colored frame when losing extender connection...
Disable USB audio codec ENAMICAMP Activate microphone amplifier Transmission Parameter Function Activate a synchronisation impulse to adjust the ENASYNC pixel clock between the CPU and CON Unit (49x series only) Pos: 62 /806-IHSE/Betrieb/UEB_Betrieb @ 5\mod_1278577614980_6.doc @ 41970 @ 1 @ 1 2017-06-06...
The DDC information of the console monitor was loaded once. Reloading is possible by repeating the operation. Pos: 64 /806-IHSE/Betrieb/Parallelbetrieb/483-xx_Parallelbedienung redundanter CPU Units @ 13\mod_1412178143567_6.doc @ 152060 @ 2 @ 1 Parallel Operation of redundant CPU Units CPU Units with a redundant connector for interconnect cables offer the possibility for a competing control by two connected CON Units.
Seite 55
When using redundant CPU Units in combination with a KVM matrix, the function of competing control will be automatically deactivated in the extender and will have to be performed by the KVM matrix. Pos: 65 /806-IHSE/Technische Daten/UEB_Technische Daten @ 5\mod_1278578165261_6.doc @ 42096 @ 1 @ 1 2017-06-06...
Draco vario ultra DisplayPort KVM Extender Specifications Pos: 66 /806-IHSE/Technische Daten/Schnittstellen/UEB_Schnittstellen @ 5\mod_1278578201870_6.doc @ 42114 @ 2 @ 1 Interfaces Pos: 67 /806-IHSE/Technische Daten/Schnittstellen/483-xx DisplayPort @ 17\mod_1484549986614_6.doc @ 177575 @ 3 @ 1 7.1.1 DisplayPort Video The video interface supports the DisplayPort 1.1 standard. All signals that comply with this standard can be transmitted.
Mouse Compatible with most 2-button, 3-button and scroll mice. Pos: 70 /806-IHSE/Technische Daten/Schnittstellen/474-xx (USB 2.0 (transparent)) @ 7\mod_1331801757497_6.doc @ 58190 @ 3 @ 1 7.1.4 USB 2.0 (transparent) KVM Extender models with transparent USB 2.0 support allow the connection of all types of USB 2.0 devices (without restriction).
Connector wiring must comply with EIA/TIA-568-B (1000BASE-T), with RJ45 connectors at both ends. All four cable wire pairs are used. Pos: 72 /806-IHSE/Technische Daten/Schnittstellen/Glasfaser SFP Typ LC @ 5\mod_1278937700855_6.doc @ 43149 @ 3 @ 1 7.1.6 Fiber SFP Type LC (Interconnect)
DTR (Data Terminal Ready) DSR (Data Set Ready) Pos: 74 /806-IHSE/Technische Daten/Schnittstellen/Serielle Schnittstelle RS422 @ 9\mod_1362475591209_6.doc @ 71309 @ 3 @ 1 7.1.8 Serial Interface RS422 KVM Extenders with a serial interface RS422 (D-Sub 9) support a differential full duplex transmission up to a Baud rate of 115,200 Baud.
Draco vario ultra DisplayPort KVM Extender 7.1.9 Analog Audio Interface The analog audio option supports a bidirectional stereo audio transmission, in near-CD quality. audio interface is a 'line level' interface and it is designed to transmit the signals of a sound card (or another 'line level' device) as well as to allow the connection of active speakers to the CON Unit.
Connections CON Unit 2x 3.5 mm stereo jack plug (audio in & audio out) Pos: 76 /806-IHSE/Technische Daten/Schnittstellen/477-xx (Digital Audio-Schnittstellen) @ 6\mod_1304585776832_6.doc @ 51309 @ 3 @ 1 7.1.10 Digital Audio Interface The digital audio option supports the unidirectional transmission of digital audio data.
Specifications Interconnect Cable Pos: 78 /806-IHSE/Technische Daten/Verbindungskabel/Verbindungskabel (Cat X) @ 5\mod_1278578406026_6.doc @ 42205 @ 3 @ 1 7.2.1 Cat X A point-to-point connection is required. Operation with several patch fields is possible. Routing over an active network component, such as an Ethernet Hub, Router or Matrix, is not allowed.
200 m (650 ft) If you use single-mode SFPs with multi-mode fibers, you normally can double the maximum acceptable cable length. Pos: 81 /806-IHSE/Technische Daten/Verbindungskabel/Verbindungskabel (LWL)_Steckverbinder 477-xx @ 5\mod_1278954447542_6.doc @ 43740 @ @ 1 Type of Connector Connector LC Connector Pos: 82 /806-IHSE/zz_Layout/Seitenumbruch @ 8\mod_1348581820516_0.doc @ 69462 @ @ 1...
Specifications Pos: 83 /806-IHSE/Technische Daten/Unterstützte Peripherie/UEB_Unterstützte Peripherie @ 5\mod_1278578478761_6.doc @ 42242 @ 2 @ 1 Supported Peripherals Pos: 84 /806-IHSE/Technische Daten/Unterstützte Peripherie/USB-HID-Geräte @ 5\mod_1278578523558_6.doc @ 42260 @ 3 @ 1 7.3.1 USB-HID Devices The KVM Extender will support most USB-HID devices, including the vast majority of keyboards and mice currently on the market.
Hot Plug Detect ML-LANE0(P) Power Out Return ML-LANE2(P) Config1/GND Power out n.c. ML-LANE1(N) Config2/GND Pos: 89 /806-IHSE/Technische Daten/Pinbelegungen/Buchse USB Typ B @ 5\mod_1278578750464_6.doc @ 42351 @ @ 1 Connector USB Type B Picture Signal Color VCC (+5VDC) Data – White Data +...
Seite 67
Signal Signal D3– D1– D2– 8..1 D4– Pos: 94 /806-IHSE/Technische Daten/Pinbelegungen/Glasfaser SFP Typ LC @ 5\mod_1278938501151_6.doc @ 43210 @ @ 1 Fiber SFP Typ LC Picture Diode Signal Data OUT Data IN Pos: 95 /806-IHSE/Technische Daten/Pinbelegungen/Stromversorgung @ 5\mod_1278578849183_6.doc @ 42423 @ @ 1...
Seite 68
D-Sub 9 (Serial) RS232 Picture Signal Signal n.c. 1....5 6...9 n.c. Pos: 97 /806-IHSE/Technische Daten/Pinbelegungen/D-Sub 9 (Seriell) RS422 Controlled Device @ 9\mod_1362477200520_6.doc @ 71349 @ @ 1 D-Sub 9 (Serial) RS422 Controlled Device Picture Signal Signal Rx-GND 1....5 6...9 Tx-GND n.c.
Seite 69
3.5 / 6.35 mm Stereo Jack Plug Picture Signal Audio IN / OUT L Audio IN / OUT R Pos: 100 /806-IHSE/Technische Daten/Pinbelegungen/RCA (Cinch) @ 5\mod_1291128877593_6.doc @ 44920 @ @ 1 RCA (Cinch) Picture Signal Data IN / OUT Pos: 101 /806-IHSE/Technische Daten/Pinbelegungen/Mini-XLR @ 5\mod_1291128998484_6.doc @ 44939 @ @ 1...
Thermal output Corresponds to power consumption in Watt (W) (see extender configurator on the website) Pos: 106 /806-IHSE/Technische Daten/Abmessungen/474-xx @ 6\mod_1304586358176_6.doc @ 51345 @ 2 @ 1 Size Devices in the 2-fold Vario Chassis 1 CPU Unit / CON Unit 145 x 147 x 41 mm (5.7"...
3.5 kg (7.7 lb) Devices in the 21-fold Vario Chassis CPU Unit / CON Unit 10.0 kg (22.1 lb) Shipping Box 14.5 kg (32.0 lb) Pos: 109 /806-IHSE/Hilfe im Problemfall/UEB_Hilfe im Problemfall @ 5\mod_1278579113839_6.doc @ 42536 @ 1 @ 1 2017-06-06...
Troubleshooting Troubleshooting Pos: 110 /806-IHSE/Hilfe im Problemfall/Allgemeine Störung/474-xx @ 9\mod_1373964024756_6.doc @ 77427 @ 2 @ 1 General Failures Diagnosis Possible Reason Measure Config.txt Parameter not set or Write parameter into Config.txt parameter saved file and save changes. without function Start Commanc #CFG ...
CPU Unit quality of interconnect cables between the units. Download DDC information from console monitors (see Chapter 6.1, Page 54). Reboot CPU if necessary. Pos: 112 /806-IHSE/Hilfe im Problemfall/Störung am USB-HID-Anschluss/483-xx @ 13\mod_1412179547240_6.doc @ 152217 @ 2 @ 1 2017-06-06...
USB device No USB-HID device Connect USB-HID device. without function USB-HID device is not Contact dealer if necessary. supported Pos: 113 /806-IHSE/Hilfe im Problemfall/Störung am seriellen Anschluss/474-xx @ 6\mod_1304586713332_6.doc @ 51418 @ 2 @ 1 2017-06-06...
Touch screen Hardware handshake Adjust serial interface to X-ON / not operational X-OFF software handshake. Pos: 114 /806-IHSE/Hilfe im Problemfall/Störung am Analog-Audio-Anschluss/474-xx @ 6\mod_1304586773051_6.doc @ 51437 @ 2 @ 1 Analog Audio Diagnosis Possible Reason Measure CON Unit: No audio connection to ...
No signal / Digital Silence at active Check LEDs at CPU Unit. LEDs 1 OK audio source Check audio format. Change audio input. Pos: 116 /806-IHSE/Hilfe im Problemfall/Störung am USB-HID-Modul-Anschluss/474-xx @ 6\mod_1304586906004_6.doc @ 51475 @ 2 @ 1 2017-06-06...
Check interconnect cable and LED 3 flashing CON Unit and CPU Unit connections. slowly Keyboard in Command Press <Esc> to leave Command Mode Mode. Pos: 117 /806-IHSE/Hilfe im Problemfall/Störung am USB-2.0-Embedded-Anschluss/474-xx @ 7\mod_1331802913522_6.doc @ 58211 @ 2 @ 1 2017-06-06...
Check installation at the CPU, LED 2 off and supported also the necessary drivers. USB 2.0 device New connection of the USB 2.0 without function device. Contact dealer if necessary. Pos: 118 /806-IHSE/zz_Layout/Seitenumbruch @ 8\mod_1348581820516_0.doc @ 69462 @ @ 1 2017-06-06...
Draco vario ultra DisplayPort KVM Extender Pos: 119 /806-IHSE/Hilfe im Problemfall/Störung am USB-2.0-Anschluss/474-xx @ 6\mod_1304586956738_6.doc @ 51494 @ 2 @ 1 USB 2.0 CPU Module CON Module Rear View Rear View Diagnosis Possible Reason Measure CPU Unit: No connection to CPU ...
Note your RMA number visibly on your shipment. Devices that are sent in without a RMA number cannot be accepted. The shipment will be sent back without being opened, postage unpaid. Pos: 121 /806-IHSE/Zertifikate/UEB_Zertifikate @ 5\mod_1278579534933_6.doc @ 42668 @ 1 @ 1 2017-06-06...
Draco vario ultra DisplayPort KVM Extender Certificates Pos: 122 /806-IHSE/Zertifikate/ATB_Europäische Konformitätserklärung @ 5\mod_1278579640901_6.doc @ 42686 @ 2 @ 1 10.1 CE Declaration Of Conformity The products listed below in the form as delivered comply with the provisions of the following European Directives:...
All power supplies are certified to the relevant major international safety standards. Pos: 123 /806-IHSE/Zertifikate/474-xx_Produktsicherheit @ 9\mod_1373964601786_6.doc @ 77511 @ 2 @ 1 10.3 Product Safety The product safety of the devices is proven by the compliance to the following standards: ...
Draco vario ultra DisplayPort KVM Extender The compliance is verified and confirmed by TÜV Süd, Germany. Pos: 124 /806-IHSE/Zertifikate/ATB_WEEE @ 5\mod_1278579673292_6.doc @ 42704 @ 2 @ 1 10.4 WEEE The manufacturer complies with the EU Directive 2012/19/EU on the prevention of waste electrical and electronic equipment (WEEE).
Glossary Glossary The following terms are commonly used in this guide or in video and KVM technology: Term Explanation AES/EBU Digital audio standard that is officially known as AES3 and that is used for carrying digital audio signals between devices. Cat X Any Cat 5e (Cat 6, Cat 7) cable Color Graphics Adapter (CGA) is an old analog...
Seite 86
Draco vario ultra DisplayPort KVM Extender Term Explanation Dual Link A DVI-D interface for resolutions up to 2560x2048 by signal transmission of up to 330 MPixel/s (24-bit) Dual-Head A system with two video connections Digital video standard, introduced by the Digital Display Working Group (http://www.ddwg.org).
Seite 87
Glossary Term Explanation Single Link A DVI-D interface for resolutions up to 1920x1200 by signal transmission of up to 165 MPixel/s (24-bit). Alternative frequencies are Full HD (1080p), 2K HD (2048x1080) and 2048x1152. Single-Head A system with one video connection Single-mode 9µ...