Herunterladen Diese Seite drucken

SSS Siedle BCM 653-0 Produktinformation Seite 6

Vorschau ausblenden Andere Handbücher für BCM 653-0:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
English
Application
Wide­angle camera with a 130° or
180° angle of aperture, mounted in
Siedle Classic. Infrared lighting and
heating integrated.
Electrical voltage
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qualified
electrician.
In the case of video systems, the fol­
lowing mounting situation must be
avoided at all costs:
• direct ajour light
• direct sunlight
• very bright image backgrounds
• highly reflective walls opposite the
camera
• lamps or direct light sources
Mounting
1 Recommended mounting height
appr. 1.60 m to centre camera.
2 Note the mounting position of the
camera, the type designation must
be legible at the top back of the
module.
3 Pick-up angle of the camera with
an angle of aperture of 130°
4 Pick-up angle of the camera with
an angle of aperture of 180° in the
full screen mode.
5 With an angle of aperture of 180°,
the pick-up angle of the camera
can be adjusted to any mounting
situation. Open the flap on the back
of the module with the aid of a
screwdriver.
6 Set the required picture excerpt
from the camera view (1 to 9) or full
screen (0) using the rotary switch.
Once the required picture excerpt
has been set, close the flap and
mount the module.
6
7 Select the picture excerpt based
on the existing mounting situation.
a Picture excerpt (1-3) top camera
alignment
b Picture excerpt (4-6) central
camera alignment
c Picture excerpt (7-9) bottom
camera alignment
Terminal assignment
BCM 653-.../BCM 658-...
TaK
In­Home bus: Video,
TbK
camera branch
Ta
Connection of the
Tb
BTLM/BTLE door loudspeaker
Vc
Actuation from the door
GND
loudspeaker to turn the
camera on
b
12 V AC supply
c
for heating
ACM 673-.../ACM 678-...
V1
video signal
V2
(two­wire FBAS)
V3
camera supply
V4
V5
Actuation of
V6
video output
CM 613-.../CM 618-...
+M
Supply voltage Video
­M
20–30 V DC
Vc
Actuation from door loud­
­
speaker for camera on
VKA Actuation of camera
distributor –M is switched
A1
Potential­free contact for
A1
additional applications
b
Power supply 12 V AC
c
for heating
Coaxial cable
L
conductor
S
shield
Installation
Installation and commissioning are
described in the relevant system
manual.

Werbung

loading