Important Notes
Touch code lock
Item no: 1717531
1 Operating Instructions for download
Use the link
www.conrad.com/downloads
complete operating instructions (or new/current versions if available). Follow the instructions
on the web page.
2 Resetting to the factory settings
Section 9.2.b of the operation instructions describes how to reset the master code to the
factory settings if the master code is unknown.
Problem
The described procedure to reset the master code fails.
Solution
Follow the below alternative procedure to reset the master code to the factory settings:
1. Prepare a small metal clip or small screwdriver.
2. Disconnect the code lock from the voltage/power supply.
3. Wait until all LEDs are off.
4. Remove the transparent glue from the pins on the back of the touch code lock. See figure
1.
5. Reconnect the code lock to the voltage/power supply.
à
The control LED will flash red for 5 seconds.
6. While the control LED is flashing red, press and hold the button # and shortcut pins No.1
and No 2. for 5 sec. using the metal clip or the small screwdriver.
à
A short sound signal is emitted.
à
The master code is reset to 1234.
à
You have reset the master code to the factory settings.
à
The master code is 1234.
Figure 1: Pins
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or the capture in
electronic data processing systems) requires prior written approval from the editor. Reprinting, also in part, is prohibited.
This publication reflects the technical status at the time of printing.
Copyright by Conrad Electronic SE.
*1717531_V1_0124_jh_hs_en 1190971915-2 I1/O1 en