Paint aerosols are flammable and therefore dangerous to use around a lit stove. Be sure to allow aerosol spray
paints to dry and ventilate the room well before lighting the stove. The use of any aerosol around a lit stove is
dangerous and care must be taken when handling aerosols.
STOVE PERFORMANCE AND TESTING
Westfire WF UNIQ32 inserts have been approved in accordance with EN 13240.
Stove model
UNIQ32 INSERT
PREPARATORY WORK AND SAFETY CHECKS
IMPORTANT WARNING:
This stove must not be installed into a chimney that serves any other heating appliance. An extractor fan may not be
fitted in the same room as the stove, as this can cause the stove to emit fumes into the room.
CHIMNEY
Chimney Connection – Flue Diameter: 125 mm
IMPORTANT: Once the stove is unpacked and checked it is necessary to remove the central bar from the flue collar
of the stove before installation. To remove: unbolt collar, remove bar and replace collar.
The stove comes pre-fitted with a European flue collar. Supplied with the stove, in a box, is a UK 125 mm / 5" flue
collar. Please ensure that you replace the collar when removing the central bar. Use a recognised brand of heat
resistant fire cement and ensure that enough cement is used to completely fill the area.
In order for the stove to perform satisfactorily, the chimney height must be sufficient to ensure an adequate
draught so as to clear the products of combustion and prevent smoke problems into the room.
Minimum tested draft
Maximum draft
Flue gas temperature
Flue gas flow
NOTE: The outlet from the chimney should be above the roof of the building in accordance with the provisions
of Building Regulations Approved Document J. If installation is into an existing chimney, then it must be sound
and have no cracks or other faults which might allow fumes into the house. Older properties, especially, may
have chimney faults or the cross section may be too large. Westfire recommend the use of a solid fuel flue lining
system for all installation into existing chimneys. All chimney systems must be used in accordance with Building
Regulations Approved Document J.
If there is no existing chimney then either a prefabricated block chimney in accordance with Building Regulations
Approved Document J or a twin walled insulated stainless steel flue to BS 1856-1. These chimneys must be fitted
in accordance with the manufacturer's instructions and Building Regulations. A single wall metal flue pipe is
suitable for connecting the stove to the chimney but is not suitable for using for the complete chimney. The con-
necting flue pipe must have a minimum diameter of 125 mm and its dimension should be not less than the size
of the outlet socket of the stove. Registered smoke exempt models burning wood only can be installed on flue
of 125mm throughout. Any bend in the chimney or connecting flue pipe should not exceed 45°. 90-degree bends
should not be used other than within 150 mm of stove rear flue outlet.
WESTFIRE · WF32
Weight
112 kg
9 | 36
Nominal heat output
Wood
Smokeless fuels
7.0 KW
UNIQ32 INSERT
12 Pa
25 Pa
317°C
7.7 g/sec
UK
N/A