WESTFIRE · WF23
WF23
dk: INSTALLATIONS- OG BRUGSVEJLEDNING
uk: INSTALLATION MANUAL AND OPERATING INSTRUCTIONS
d: INSTALLATIONS- UND GEBRAUCHSANWEISUNG
fr: NOTICE D'INSTALLATION ET D'UTILISATION
dansk ingeniørkunst
1

Werbung

loading

Inhaltszusammenfassung für Westfire WF23

  • Seite 1 WESTFIRE · WF23 WF23 dk: INSTALLATIONS- OG BRUGSVEJLEDNING uk: INSTALLATION MANUAL AND OPERATING INSTRUCTIONS d: INSTALLATIONS- UND GEBRAUCHSANWEISUNG fr: NOTICE D’INSTALLATION ET D’UTILISATION dansk ingeniørkunst...
  • Seite 2 ( Vi henviser til nBL´s hjemmeside www.nbl.sintef.no ) Vi ønsker Dem tillykke med Deres nye brændeovn fra Westfire ApS. For at De kan få størst mulig glæde af Deres nye brændeovn og for at der ikke skal opstå problemer, beder vi Dem gennemlæse denne vejledning. Vi henviser til at, ”alle lokale forordninger, inklusive dem der henviser til nationale og europæiske standarder, skal overholdes...
  • Seite 3 Westfire 23 ovne er forsynet med en reguleringsventil til sekundærluft der skal sikre ilt til forbrændingen. Tilsodning af skorsten kan skyldes brug af vådt træ eller at forbrændingen får for lidt sekundærluft. Ved fyring i brændeovnen vil alle overflader blive varme og der skal udvises fornøden forsigtighed. Ved betjen- garanti ing af spjæld og håndtag, skal der bruges handske.
  • Seite 4 For further information on installing and using fireplaces and wood burning stoves, please see the relevant building regulations that apply to the country in which WESTFIRE WF UNIQ 23 has been approved, as well as the relevant brochure on the correct use of wood burning stoves available from your local stove supplier or your Chim- ney sweep.
  • Seite 5 The WESTFIRE WF UNIQ 23 can be fitted as an option with a closed air supply collar; this enables the stove to take If there is no existing chimney then either a prefabricated block chimney in accordance with Building Regulations combustion air (primary, secondary and tertiary) directly from outside via 100mm pipe from the stove.
  • Seite 6 6. Once fire is hot close primary air lever (push in). This will close off the primary air control to the stove. If the The WESTFIRE UNIQ 23 stove is factory set up with a top flue outlet, this can altered to a rear connection by un- stove begins to die down to much when the primary is closed, open slider again and leave open for another bolting top collar and rear cover plate and exchanging collar and plate.
  • Seite 7 Ireland) Order 1981, applies in Northern Ireland. Therefore it is a requirement that fuels burnt or obtained for use sOLid sMOkeLess fueLs - The WESTFIRE WF UNIQ 23 stove is suitable for use with good quality smoke less fuels. in smoke control areas have been “authorised” in Regulations and that appliances used to burn solid fuel in those The stove will burn best when burning wood.
  • Seite 8: Troubleshooting

    The guarantee does not cover damage to replaceable parts, transport costs associated with repairs under warranty or the installation/dismantling of the stove in connection with repairs under warranty. Warning! Any unauthorised modification of the appliance is forbidden. Only replacement parts recommended by Westfire ApS should be used for repairs.
  • Seite 9 2. Left Mid Baffle Brick 3. Right Mid Baffle Brick Wir beglückwünschen Sie zum Erwerb Ihres neuen Westfire Kaminofens! Damit Sie viel Freude daran haben, bit- 4. Rear Brick ten wir Sie, diese Gebrauchsanweisung sorgfältig durchzulesen, denn so lassen sich Probleme vermeiden.
  • Seite 10: Garantie

    Verbrennung hin. In diesem Fall muss mehr Sekundärluft zugeführt werden. Vor dem Anzünden sind die Zugverhältnisse zu überprüfen. Dies kann mithilfe eines zusammengeknüllten Stückes Die Garantie erlischt bei unbefugten technischen Änderungen am Ofen. Bei Reparaturen sind ausschließlich von der Fa. Westfire ApS empfohlene Ersatzteile zu verwenden.
  • Seite 11 (celui-ci doit rester ouvert et avoir une capacité suffisante lorsque le poêle est allumé), ou un système d’air frais raccordé au poêle. air secondaire Tous les poêles de Westfire sont équipés d’un inverseur de fumées qui assure un transport des fumées suffisamment long. Wf 23 Ouverture à 60 % raCCOrd aVeC La CHeMinÉe...
  • Seite 12: Entretien

    La garantie ne couvre pas les dommages sur des pièces qui peuvent être changées, ni les frais de transport suite à des réparations sous garantie, ni le montage/démontage des réparations sous garantie. Avertissement: il est interdit de procéder à des modifications non autorisées de ce système. En cas de réparation, utilisez uniquement des pièces détachées recommandées par Westfire ApS.
  • Seite 13 WESTFIRE 2011 | WF23 1.0 TøMRERVEJ 3 | DK-6800 VARDE | TELEFON +45 7522 5352 | FAx +45 7522 1352 | WWW.WESTFIRE.DK | E-MAIL: INFO@WESTFIRE.DK...