SWITCHING THE APPLIANCE ON / OFF
To shut down the appliance, press and hold
"Switch off" by pressing
To switch the appliance on, press and hold
To avoid the commands being changed by children, you may lock your
appliance's commands by pressing and holding
Select "Lock"
Do the same to unlock the commands by selecting "Unlock"
Used to detect variations in temperature related to the opening and closing of your windows.
If you forget to switch off your appliance when a window is open for a long time, this function lets
you get around this and prevents your appliance from heating up unnecessarily.
The appliance automatically switches to Frost Protection mode (7°C) when it detects an open
window and rises to the setpoint temperature when it detects that the window has been closed (the
detection time is variable).
We do not recommend using this function in corridors and rooms located near an entry door which
opens to the outside.