Herunterladen Diese Seite drucken

clage Zip HydroTap G4 BCS 160 Gebrauchsanleitung Seite 41

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

To change the Filter: (See also section C)
1. Open the door of the under sink unit.
2. Relieve system pressure via the filter flush stop cock, a quick
open and close will do. Use the bucket to catch the discharge.
3. Grasp filter cartridge and rotate the cartridge a quarter turn to
the left, then gently pull down.
4. Caution: a small amount of water will drip as the cartridge is
removed.
5. Do not tilt the cartridge as water may spill from it if tilted.
6. Unpack replacement cartridge and remove sanitary cap, write
today's date where shown on the label.
7. Avoid touching the filter O-rings and filter opening as this may
cause bacterial contamination of the cartridge.
8. Moisten the O-rings with water, align the front cartridge label
to the left (as shown in the diagram for filter cartridge replace-
ment), and push the new cartridge into the filter head.
9. Turn the cartridge a quarter turn to the right until the cartridge
comes to complete stop and is locked into position, with the
front label facing forward.
10. Initiate the filter flush programme by scrolling through the menu
screen (See section C).
11. Close the door to secure the appliance.
12. Adjust the filter settings in section F - filter - litres and days used.
13. Dispose of the used filter correctly.
Filter Maintenance
1
2
Warning: If the Zip HydroTap
is switched off for a long
period of time (e.g. More
1
than a weekend), run water
through the chilled water
2
outlet for at least 5 minutes
before consumption.
41

Werbung

loading

Diese Anleitung auch für:

Zip hydrotap g4 bcs 175