Protection class
The specified vibration value was measured with a
standardised test procedure. It can be used to
compare products or to make an initial assess-
ment of the exposure. The vibration emissions may differ
from the specified value, depending on how the power
tool is used. Operating personnel must be protected with
defined safety measures based on the estimated expo-
sure under the actual conditions of use (these must take
into account all phases of the operating cycle, e.g. the
times when the power tool is switched OFF and the times
it is switched ON, but is not under load).
2.4 o
perAting conditions
Temperature range during operation: 0 to +50°C
Relative air humidity: 95% at +10°C not condensed
3.
haNDLINg
3.1 p
rotectiVe deVices
3.1.1 p
rotection of the mAchine
s
tArting current limitAtion
The electronically controlled soft starting provides for jerk-
free starting of the machine. Due to the low machine star-
ting current a 16 A fuse is adequate.
t
-
emperAture
dependent oVerloAd protection
For protection against overheating, when a critical tem-
perature is reached the electronic safety feature switches
into the cool-down mode. The machine then continues
to run at a speed of approx: 1100min
constant speed control is deactivated. After a cool-down
time of approx. 10 - 20 s the machine is again ready for
operation. Turn the machine off and back on again to acti-
vate the electronic constant speed control. With the tool at
operating temperature the temperature-dependent over-
load protection reacts correspondingly earlier.
u
/ r
nderVoltAge
estArting protection
On short-time failure of the power voltage (plug discon-
nected, instable power mains etc.) the machine will stop.
When the power voltage recovers, the machine must be
turned OFF and back ON again. Then the machine is
ready for operation.
3.2 g
rinding tools
Use only grinding tools whose ad-
missible maximum speed is equal
to or higher than the no-load
speed of the machine.
Use only clean tools!
II
3.2.1 c
Hold spindle against turning at wrench flats with open-
end wrench and release the clamping nut
/ o
PERaTIoN
Put the clamping shaft of the grinding tool in the collet
chuck.Tighten down tensioning nut.
must be correctly mounted and must rotate freely. Per-
form a trial run a minimum over a period of 30 seconds
without load. Do not used grinding tools which are dam-
aged, which do not run true or which vibrate!
-1
and the electronic
3.3 w
To achieve an optimum result, move tool uniformly back
and forth with light pressure. The electronic constant con-
trol maintains the speed nearly constant during idling and
work under load and assures a uniform result. Excessive
pressure lessens the working capability of the machine,
as well as the life of the tool. The machine is equipped
with an electronic control and integrated overload pro-
tection. If the machine is overloaded, the speed will drop
drastically. Immediately take the load off the machine and
allow to run for a short time without load.
/
hAnging
fitting the grinding tool
The grinding tools must run true. Do not use grind-
ing tools which have gotten out of round. Trial run!
Check grinding tools before use. The grinding tool
orKing instructions