The control unit with microprocessor CORE can be used with motors having a power not exceeding
750W.
a) The wire connections and the operating logic should be in compliance with regulations in
force.
b) The cables featuring different voltage should be physically separated, or adequately insulated
by an additional insulation of at least 1 mm.
c) The cables should be further fastened in proximity to the terminals.
d) Check all connections before powering the unit.
e) Check that setting of the Dip-Switches are the required ones.
f) Normally Closed inputs which are not in use should be short-circuited.
Terminals
L-N-GND
MOT-COM-MOT
N-BLINK
SWO
SWC
PHOT (CLOSE)
STOP
COM
P.P. (OPEN)
24 VAC
SCA
ENC1
8
All manuals and user guides at all-guides.com
CORE control unit with microcontroller
GENERAL WARNINGS
INPUT/OUTPUT FUNCTIONS
Function
Description
Input, 230VAC 50Hz (CORE)
Power supply
Input, 115VAC 50/60Hz (CORE 115V))
(1-Phase/2-Neutral/GND-Ground connection)
Connection to motor:
Motor
(MOT-move/COM-Common/MOT-move)
Output, connection to Flashing light
LAMP
CORE: 230 Vac 40W max.
CORE 115V: 115 Vac 40W max.
SWO
Input, OPENING limit switch (Normally Closed contact)
SWC
Input, CLOSING limit switch (Normally Closed contact)
Input, connection to safety devices, Normally Closed (N.C.)
contact (e.g. photocells): configurable through DIP3).
PHOT
In "Service man" mode, it activates the CLOSE function. In
this case connect a Normally Open (N.O.) key.
STOP
Input, STOP key (N.C. contact)
COM
Common, all control inputs.
Input, step-by-step key (N.O. contact).
Step-by-Step
In "Service man" mode, it activates the OPEN control fun-
ction.
24Vac
Output, 24Vac/400mA max accessory power supply.
Contact free from voltage, not insulated for the connection
of open gate indicator lamp.
SCA
Open contact with closed door leaf. Flashing light during
the door leaf movement. With open door leaf, the contact
is closed.
Input, connection of the encoder. If it is connected to the
control unit, it automatically detects the presence of the
encoder and, after the first operation at reduced speed, it
ENCODER
sets braking in both opening and closing phases
The sensitivity of the encoder can be adjusted by the TW
trimmer.