FAULTS: CAUSES AND CURES
7
7.1
Fault-finding procedures
Should any fault occur during the use of the machine, turn it off, and isolate it from the electrical
supply. Any works dealing with the electrical system or supply of the machine can only be carried
out by a qualified electrician.
7.2
Trouble-shooting guide
Trouble
Motor is not running
Motor stops during the cutting,
but can be restarted after a
short period (overload
protection)
No water on the blade
24
Possible source
No electricity
Connection cable section too
small
Defective connection cable
Defective switch
Defective motor
Cutting feed speed too quick
Blade is blunt or glazed
Defective blade
Wrong blade specification for
the application
Not enough water in the pan
Water supply system is blocked
up
Water pump is not working
TR 232_MAN_EN
Resolution
Check the electrical supply
(fuse for example)
Change connection cable
Change connection cable
CAUTION : can only be solved
by qualified electrician
Change motor or contact motor
manufacturer
Cut slowly
Sharpen the blade in
calcareous stone
Change blade
Change blade
Refill the water pan
Clean water supply system
Change the pump