3.11 Electrical connections
Check that:
The voltage/phase supply corresponds to the information indicated on the motor plate.
Available power supply must have ground connection in conformity with safety regulations.
The connecting cables should have at least a 2.5mm
3.12 Water cooling system
Fill the TR 232 with clean water up to 1cm under the top edge of the water tray. The pump will
switch on together with motor.
Ensure that water is delivered adequately to the blade, as insufficient water supply may result in
premature failure of the diamond blade.
The water pump must never run without water. Always make sure that there is enough water in
the pan and refill if necessary.
In case of frost, empty the water cooling system from its water.
3.13 Starting the machine
Connect your machine to the electric source. To start the machine, press the green button on the
switch. To stop the machine, press the red button. This one is also an emergency stop key.