Herunterladen Diese Seite drucken

HYDAC ELECTRONIC HPT 1000 Kurzanleitung Seite 9

Vorschau ausblenden Andere Handbücher für HPT 1000:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Process data (cyclic transmission)
 Pressure (current measured value in bar): Amount of decimal places depending on the
measuring range
 Switching condition of SSC2 (switching signal channel 2)
 Switching condition of SSC1 (switching signal channel 1)
Process data input (ProcessData)
Bit length: 16
Data type: 16-bit Record (Subindex not supported)
Octet 0
bit offset
15
14
Subindex
element
13
12
bit
Technical data
Input data
Measuring range (bar)
Overload pressure (bar)
Burst pressure (bar)
Mechanical connection
Tightening torque, recommended
Parts in contact with fluid
Output data
Output Signal
Switching outputs
Analogue output, permitted load
resistance
1)
Accuracy
acc. to DIN 16086
2)
Max. setting
Accuracy at min. setting (B.F.S.L)
Temperature compensation, zero point
and span
Rise time
Long-term drift
IO-Link Communication
IO-Link Revision
Port Class
Transmission Rate, baud rate
Minimum Cycle Time
Process data width
SIO Mode Supported
Sensor profile
M-Sequence Capability
13
12
11
10
9
Measured value
11
10
9
8
7
16
32
100
G 1/4 A ISO 1179-2 , male, with orifice
20 Nm
Mechanical connector: stainless steel; Seal: FKM
HPT 1400(S)
IO-Link V1.1
Further switching output or analogue output as an option
PNP transistor switching output (parameterizable: PNP,
NPN or Push-Pull); optional additional PushPull transistor
switching output
Switching current: max. 250 mA for each switching output
4 .. 20 mA,
0 .. 10 V,
 ± 0.5 % FS typ.
 ± 1.0 % FS max.
 ± 0.25 % FS typ.
 ± 0.5 % FS max.
 ± 0.015 % / °C typ.
 ± 0.025 % / °C max.
 5 ms
 ± 0.3 % FS typ. / year
V1.1
A and B
38.4 kBaud (COM2)
2.5 ms
16 Bit (14 measured value- + 2 switching Bits) SIO
Yes
GPS
PREOPERATE = TYPE_1_V (8 0D-Bytes)
OPERATE = TYPE_2_2 (1 OD-Byte) ISDU supported
Octet 1
8
7
6
5
4
6
5
4
3
2
25
40
60
100
50
80
120
200
125
200
300
500
R
= U
– 8 V / 20 mA [kΩ],
Lmax
B
load resist. max. 500 Ω
R
= 2 kΩ
Lmin
 ± 0.25 % FS typ.
 ± 0.5 % FS max.
 ± 0.15 % / °C typ.
 ± 0.25 % / °C max.
 ± 0.008 % / °C typ.
 ± 0.015 % / °C max.
 5 ms
 ± 0.1 % FS typ. / Jahr
3
2
1
0
SSC2
SSC1
1
0
250
400
600
500
800
1000
1250 2000
2000
HPT 1700(S)

Werbung

loading

Diese Anleitung auch für:

Hpt 1000s