Herunterladen Diese Seite drucken

HYDAC ELECTRONIC HPT 1000 Kurzanleitung Seite 7

Vorschau ausblenden Andere Handbücher für HPT 1000:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Preface
This document is only a quick guide that is intended to enable our customers to have
paperless, digital access to product documentation. You can obtain the detailed operating
manuals and the data sheets for the HPT 1000 / 1000S IO-Link series at www.hydac.com
(by entering „HPT 1000" in the search field).
Safety notice
Before commissioning, check the instrument and any accessories supplied. Before starting
up the device, read the detailed operating instructions and make sure that the device is
suitable for your application.
Incorrect handling or non-compliance with the instructions for use or the technical
specifications can lead to property damage and / or personal injury.
Exclusion of liability
This quick guide only provide brief operating and set up specifications for experienced users,
so knowledge of the comprehensive operating manual is essential when using the device for
the first time. Liability for incorrect installation or improper use of the device is not accepted.
In the case of translation, only the text of the original German operating manual is legally valid.
Brief description of the series HPT 1000 / 1000S IO-Link
The HPT 1000 / 1000S IO-Link is a digital pressure transmitter that is used to record relative
pressures in hydraulics and pneumatics. The measured values are digitized and made
available cyclically via the IO-Link interface. The internal device temperature is also available
on request. The smart version - the HPT 1000S – can record and store additional operating
and application data, which are available on request, too. Depending on the model, the device
offers the following functions:
 Provision and parameterization of the measured values and switching points via IO-Link
interface
 Supports IO-Link specification V1.1 and SIO mode
 Data recording function / acquisition of additional operating and diagnostic data
 Adaptation to the respective application through specific parameter setting
 Further switching output or analogue output (0 .. 10 V or 4 .. 20 mA) as an option
 Small, compact design, robust sensor cell with a thin-film strain gauge on a stainless steel
membrane
 Excellent temperature and EMC properties
Scope of delivery
The device is delivered with factory settings without accessories. This quick guide is
supplemented by a detailed operating manual and a data sheet. Both documents are available
at www.hydac.com (by entering „HPT 1000" in the search field)..