Herunterladen Diese Seite drucken

CombiSteel MVC-458 Gebrauchsanweisung Seite 8

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3. Cleaning
To prevent any electrical shock hazards or injury by rotating circulation fan, always
WARNING
disconnect the power cord plug from the wall outlet before cleaning.
3.1 Exterior and cooler compartment
Wipe with a soft, dry cloth. If very soiled, wipe with a cloth that has been moistened with a detergent. Then wipe
with a cloth that has been dipped in water.
Do not splash water directly onto the cooler and do not wash with water.
WARNING
Short-circuiting and electrical shock could result.
Clean the cooler regularly to keep it clean at all times.
Never use polishing powder, soap powder, gasoline, oil or hot water
as these will damage the painting and plastic components.
3.2 Checks after cleaning
To ensure the safety, perform the following checks after cleaning.
Is the power cord plug firmly inserted into a dedicated wall outlet? Confirm that the plug is not abnormally
hot.
Check the power cord for cracks and damage. Should the slightest irregularity be observed, contact the
dealer from whom you purchased this unit or our customer service.
4. Troubleshooting
Please check the following items if you encounter problems with the unit. If the problem continues after taking
the proper remedial actions, disconnect the power cord plug from the wall outlet. Transfer the items stored in
the cooler to a box or other container. Then contact the dealer from whom you purchased this unit and be ready
to provide information as listed in the table below.
Problems
Faulty electrical contact
The unit is not
Poor electrical power
operating
Thermostat set to the minimum position
Unit is exposed to direct sunlight.
Thermostat is not properly adjusted.
Door(s) not properly closed
Not reaching the
Products poorly distributed or excess
desired
product load
temperature
Clogged condenser
Blocked grills
For models with electronic temperature
controller, indicates E0 or E1.
The unit is not properly levelled.
Excessive noise
Something is in contact with the appliance,
e.g. boxes, mops, brushes, etc.
Water on the floor
Drain hose is outside of the drain pan.
Possible Causes
www.combisteel.com
Possible Solutions
Verify electrical connections.
Check the power connection and
electrical outlet.
Adjust the thermostat setting to a
higher number.
Relocate the unit to a shaded area.
Adjust the thermostat setting to a
higher number.
Check the levelling of the unit and
door seal.
Redistribute the product load
according start instructions.
Clean the condenser.
Clean the grills of any debris collected.
Unplug the unit from the outlet. If the
error continues, contact an authorized
service technician.
Level the unit, making sure all the feet
are in firm contact with the floor.
Keep the objects away from the
appliance.
Lovate the hose in the drain pan.
8

Werbung

loading