CASTOR REPLACEMENT
1.
Remove the existing castors using a short reach 8 mm Allen key (available from
Aidapt).
2.
Replacement M12x35 bolts are
provided with each castor, the
removed bolts should be disposed
of.
3.
Apply a thread locking fluid to the
bolt to lock the assembly securely.
We recommend the use of Bondloc
B243 or Locktite 243.
4.
Assembly should be screwed
tightly and the castor should sit
flush with the frame. (i.e. there should be no gap between the castor and the
frame)
NB: Where leg extension pins are in place it is recommended that the extension pins
are replaced at the same time as the castor.
For further technical details contact Aidapt.
COMMODE BUCKET
To remove the commode bucket, simply slide the bucket out from the chrome runners at the
rear of the commode. Cover the top of the bucket to avoid splashing, carefully dispose of the
contents into a proper sluice or WC. Never use an open drain, sink or basin. This could cause
a serious health risk. To avoid the possibility of trapping, do not slide the commode pan on
or off the rails while somebody is sitting on the chair.
Clean out the residue with a suitable disinfectant and refit to the commode after use
NB. Always remove the commode bucket prior to removing the grey horseshoe seat.
CLEANING
A useful guide to decontamination is MHRA leaflet DB2003(06).
Do not use abrasive cleaners as this could damage the surface of the equipment. For
cleaning, wipe with a clean cloth soaked in detergent solution and wring out. Depending on
the detergent manufacturer's instructions the solution may be heated.
Wipe all surfaces of the equipment and the cloth should be re-immersed periodically and the
detergent changed frequently. The detergent should be rinsed or wiped off using a clean
cloth immersed in clean water and wrung out.
To disinfect make sure the equipment has been cleaned and dried and then wipe over with a
clean cloth and a compatible liquid disinfectant. After disinfecting clean with clean water
and dry.
When using detergent or disinfectants then please refer to manufacturers' instructions and if
unsure then consult your local Infection Control Specialist for advice.
This product is not suitable for cleaning with moist heat or autoclaving.