Herunterladen Diese Seite drucken

EuroLite RGB Spot 10 mm Bedienungsanleitung Seite 19

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

On the rear panel of the EUROLITE LED PAR-Spot you can find an XLR-jack and an XLR-plug, which can
be used for connecting several devices.
Choose the device which is to control the effects. This device then works as master-device and controls all
other slave-devices, which are to be connected to the master-device via a stereo shielded cable. Connect
the OUT-jack with the IN-plug of the next device.
Set DIP Switch 10 on 0 in order to determine the Master device, then choose the desired mode. (see
OPERATION)
Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
OPERATION
The device has two operating modes. It can be operated via DIP Switches or it can be run in DMX-controlled
mode.
After you connected the spot to the mains, the EUROLITE LED PAR-Spot starts running.
International
L
N
19/40
51913624_V_1_2.DOC