HEATER
Whenever a WHIRLPOOL or HYDROSONIC
function is activated, the user can switch on the
heater to keep the water in the bathtub at a steady
temperature.
Press the "HEATER" button to switch on.
As the heater comes on, the display will indicate its
"on" status (#) for a few seconds, then revert to the
previous item.
Press the "HEATER" button to switch off.
The heater switches off, and the display indicates
the "off" status for a few seconds before reverting
to the previous item.
AUTOMATIC SHUTOFF: When the function currently selected ceases operating, the heater will also shut off.
DISINFECTION
When the system is switched off using the "O/I" button and after at least one Hydrosonic, WhirlpooI or Blower
cycle has been selected, a DISINFECTION cycle will follow.
During Disinfection, both the remote control and the control panel are deactivated except for the "O/I" and
"ALARM" buttons, which can be used to suspend the Disinfection cycle at any given moment.
RUNNING THE DISINFECTION CYCLE
Be sure to VACATE THE
Disinfection takes place.
STArT
DiSiNFECTioN?
Display showing Disinfection
prompt
Press "ENTER" to start the Disinfection.
The display shows a warning message for a
few seconds. Thereafter, the display indicates
Disinfection in progress; The disinfection cycle is is
automatic and includes the following steps:
whirlpool system operates for 1 minute
approximately, with cleansing fluid supplied
from the dispenser;
pause of 10 minutes allowing disinfectant action;
suction valve closes.
HYDROSONIC - Hydrosilence
BATHTUB before
#
15
36
C
20:30
o
hEATEr oN
Display indicating Heater ON
15
36
C
20:30
o
hEATEr oFF
Display indicating Heater OFF
lEAVE
BAThTUB
DiSiNFECTioN
rUNNiNG
EN