ECO SENSOR OPERATION
The ECO sensor can detect the human activity level in a room and adjust the setting temperature automatically
to achieve energy saving.
Wind Mode
• The energy saving is more effective after the ECO SENSOR OPERATION keeps working for more than
2 hours.
• In the ECO SENSOR OPERATION, the energy consumption saved by the air conditioner varies with the
activity level.
• Comfort airflow (direct airflow operation)(page 15) can further reduce the energy consumption.
• After detecting that the person leaves the room for 20 minutes, the air conditioner turns to the ECO modes
according to the settings in the remote controller as shown in the table below, but the preset temperature
in the remote controller remain unchanged.
• When the air conditioner works in powerful operation, setting the ECO mode will cancel the powerful operation.
Operation mode
Heating
Cooling
Dehumidifying
Auto
NOTE
By pressing (POWERFUL) button, ECO operation is cancelled.
After auto restart, ECO operation is cancelled and previous operation mode will start.
The eco sensor detects changes to the infrared generated by human bodies. Therefore, the accuracy of eco sensor
may be affected negatively in the following cases:
• The activity level is very low (reading, watching TV, etc.) or human bodies are blocked by a screen, cabinet, or
glass board.
• The indoor temperature is very high and exceeds or approaches the human body temperature (when the
refrigeration just begins).
• The person wears thick clothes and turns his/her back to the air conditioner.
• Curtains or plant leaves swing due to pet movement or airflow.
By pressing the
1
HEATING, DEHUMIDIFYING or COOLING operations, the air
conditioner performs the ECO SENSOR operation.
■ To start ECO sensor operation
Press the
"
• The ECO SENSOR automatically adjusts the indoor temperature
according to the activity level in the room.
■ To cancel ECO sensor operation
• Press the
• Press the
"
Operation Description
Reduces the preset temperature in one of the
following cases:
• High activity level
• High indoor temperature
Raises the preset temperature in one of the
following cases:
• Low activity level
• Low indoor temperature
Increases the preset temperature in one of the
following cases:
• Low activity level
• Low indoor temperature
Energy-saving operation in auto mode.
(ECO SENSOR) button during AUTO,
(ECO SENSOR) button.
" is displayed on the LCD.
(START/STOP) button. Or
(ECO SENSOR) button again.
" disappears from the LCD.
- 16 -
Actions in case of no person
Decreases the temperature by
2°C.
Increases the temperature by
2°C.
Increases the temperature by
1°C.
Energy-saving operation in
auto mode.