Use in winter season
We recommend to install the trough drinker into a water circuit means of a connection set ¾" (103.3004) or 1" (103.3007). The water circuit is then connec-
ted to a SUEVIA Heating Unit. This guarantees a frost-protected use throughout the year. See heating unit instructions.
Heated version
• One or two heating elements (131.0524, 24 V, 80 W) can be installed at any time to keep water inside of the bowl frost-free.
• For frost protection of the water line a frost protection heating cable 101.0861 (24 V, 20 W, 2 m / 6,56 ft), or 101.1863 (24 V, 30 W, 3 m / 9,84 ft) can be
supplied. The heating cable should be wrapped around the feed pipe and connected to the heating element of the drinker in parallel to the power supply
cable, coming from the transformer. If this heating cable is installed on plastic pipes, make sure that this water pipe is suited for warm and cold water. For
better heat distribution the water pipe has to be wrapped first with an aluminium adhesive tape (101.1099).
• For increased frost protection of the valve an installation of a valve heating is recommended (131.0527, 24 V, 7 W).
 For power supply a transformer is necessary. Transformer should be mounted outside of animal's reach! Only cold weather conditions require constant
heating. When it is not so cold outside, heating can be interrupted by drawing out the transformer's plug. As alternative to this for automatic switch on/off of
the treansformer we recommend to install SUEVIA Thermostat (101.0389).
Electric connection
Using 24 V there is no danger for the animals.
All installation, maintenance and inspection works must be carried out only by an authorised and qualified specialist.
We recommend to ground the drinker due to electrostatic discharges.
Local norms must be respected.
The assembly instruction of the respective electric devices are to be followed.
Fire prevention
A minimum distance of 30 mm to flammable material should be held.
Protection bar
A protection bar (131.1393) can be installed as option for protection of the drinker.
Connection to a water circuit ¾" (103.3004), 1" (103.3007)
Mounting of the heating
element 131.0524
131.0524
or
View of the drainage plug
from below
Mounted protection bar
View of the drainage plug
from inside
131.1393
5